I am working on the analysis of a system where I would like to minimize the amount of imposed damping to maximize elastic response. However, I don't want to cause issues with numerical stability which arise when the linear and quadratic bulk viscosities are set to zero. Is there an acceptable range of bulk viscosity values that can be calculated or some procedure by which they can be minimized without creating an unstable model?