You can use DNV RP B401 , assume 2000 Amp*hr/kg anode, find the Current Density (mA/m2) after oxygen at the waterdepth to arrive at necessary anode mass for a given design life.
Many thanks for this answer, but my question is on what distances from the pipeline in the soil, anode bed should be installed? I found some recommendation min 30 m., So, is there any standard recommendations (30, 50 or 100 m)?