If ethyl group in ionic liquid (1-Ethyl-3-methylimidazolium) is replaced by methyl group. What is the effect of resulted moiety in pretreatment? Please elaborate with respect to polarity and K- T parameters?
It will go down, since you will get a symmetric molecule, with higher viscosity and lower polarity.
I completely agree with the answer given by Boyan Iliev.
For the influence of the alkyl chain on the Ionic liquid viscosity, see this book chapter :
http://pubs.acs.org/doi/abs/10.1021/bk-2002-0819.ch004
(K. Seddon published plenty of work about ionic liquid properties)
About the K-T parameters and polarity, this paper is particularly interesting in my opinion :
http://pubs.rsc.org/en/content/articlelanding/2011/cp/c1cp21262a#!divAbstract
Hope it helps you.
Best regards.
Thank you very much Xavier.
It helps me alot
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
I'm currently working on calculating the collision cross section (CCS) for various ions, and I'm facing challenges when dealing with sodiated and multiply charged ions. Most of the resources I’ve...
08 August 2024 8,329 0 View
I need to do some experiment with it in liquid form.
07 August 2024 613 3 View
I am trying to recover liquid CO2 from a mixture of 0.6 CO2, 0.3 N2, and 0.1 O2. My aim is to recover about 99% liquid CO2 at the bottom of the column and make sure the amount of gaseous CO2...
06 August 2024 4,611 0 View
I have prepared a liquid broth containing Yeast (S. Cerevisiae) that i need to add from it to fermentation media of lignocellulosic hydrolysate. I need to know based on what parameters do we add...
06 August 2024 662 1 View
What is the best way to freeze the rat brain - liquid nitrogen, Dry ice , isopentane - after isolation for later protein investigation by Elisa?
01 August 2024 1,722 1 View
I am currently working on a project involving liposomes and need to determine the maximum volume of siRNA that can be added to a 2.5 mL liposome solution with a total lipid concentration of 10...
30 July 2024 6,420 1 View
Can an analytical method's limit of quantification (LOQ) be outside its linear dynamic range, or is it always required to be within it? Please provide a thorough explanation supported by verified...
29 July 2024 7,198 9 View
I am doing research on wear mechanism of the additive manufactured metal parts under dry condition. Please share the reference to start the analytical modelling of the wear prediction.
29 July 2024 6,115 0 View
Dear Siesta Users, I installed Siesta 5.0.1 and I want to use Grimme's D3 correction. According to the 5.0.1 manual, I could use a few parameters to include the D3 correction in the...
27 July 2024 5,748 0 View