30 September 2016 10 2K Report

Hello,

I'm looking to determine the residual strain after the release of a MEMS structure.

I fabricated micro-bolometers above a sacrificial polyimide layer. On removal of the polyimide the bolometer membrane is deformed. Electrically the bolometer is still intact but from SEM images I can see it is under tensile stress while the metal supporting arms are under compressive stress.

I have attached an SEM image showing the bolometer after the sacrificial removal of the polyimide layer.

Obviously I'd like to tune this stress out of my structure. I could do this experimentally but what I think is best to do is simulate some strategies before committing to a laborious and costly fabrication effort.

I have access to COMSOL and have been looking at tutorials on how to determine the residual stress in a structure. However, knowing little about mechanical engineering, I'm still not entirely sure how best to tackle the problem. 

Can anyone offer me some assistance?

Many thanks,

James

More James Grant's questions See All
Similar questions and discussions