Please suggest a way to conduct low voltage poly ether sulfon membrane.
PES (polyethersulfon) membrane is an insulator and does not conduct electricity. PES must be a porous material to serve as a membrane. There are numerous conductive composites based on PES. Search the literature which one fits your requirements.
Please look at the following below links which may help you in your analysis:
https://pdfs.semanticscholar.org/5d88/0fdf651ece722332338d304ebcd692cf0f01.pdf
https://www.researchgate.net/publication/332551565_DEVELOPMENT_OF_A_NEW_COMPOSITE_CONDUCTIVE_POROUS_MEMBRANE_PESPANIrGO_FOR_ELECTROCHEMICAL_FOULING_MITIGATION
https://www.sbir.gov/sbirsearch/detail/372081
Thanks
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
I'm currently working on calculating the collision cross section (CCS) for various ions, and I'm facing challenges when dealing with sodiated and multiply charged ions. Most of the resources I’ve...
08 August 2024 8,329 0 View
During low-temperature testing, new diffraction peaks that appear could be indicative of several phenomena. In one of our tests, we observed notable new peaks around 40° and 45° in a specific...
06 August 2024 726 3 View
I am having an issue with my gel image where my PCR product is not appearing very bright on the gel. When I perform gel extraction, the A260/280 purity value is very low. I used the Qiagen gel...
05 August 2024 9,798 3 View
I have protein-membrane simulations (PDB, PSF, DCD) and have noticed that water molecules near the protein are not visible in the simulations. How can I fix this issue? Is there a way to place the...
04 August 2024 1,200 2 View
What is the method for analytically calculating the wear and service life of polymer-polymer sliding pairs?
04 August 2024 1,078 1 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
A typical reforming section in a large-scale Haber-Bosch process (Figure 1) comprises two reactors. A mixture of methane (CH4) and steam (H2O) is fed into a primary reformer to produce syngas via...
01 August 2024 7,051 5 View
I am currently working on a project involving liposomes and need to determine the maximum volume of siRNA that can be added to a 2.5 mL liposome solution with a total lipid concentration of 10...
30 July 2024 6,420 1 View