In XRD data, they mention STEPTIME as 19.200001 and STEPSIZE as 0.018827. From this data how can I calculate the scan rate? Please help me.
Thank you
Your's sincerely
Syam Kandula
Step time is in seconds/step, step size is in degree/step, range is in degree, (your 2 theta range) there you can calculate yous scan rate in degree/second
Thank you very much to both of them....its a very useful help for me.....
Hi, I am trying to make a carbon ultramicroellectrode but each time I am facing the problem of current leakage. I am following the exact same fabrication procedure but still not getting the good...
08 September 2018 144 0 View
I have prepared the powder sample, which is active for pseudosupercapacitor application. I am interested to check the supercapacitor device in a solid state using a gel electrolyte. So, any one...
01 February 2018 4,768 4 View
Most of the cases aggregation leads to red shift in absorption band gap. This phenomenon is more prominent in the case of Au-semiconductor heterostructures but Ag aggregates does not show much...
01 February 2016 5,089 1 View
I have run the XRD for pure cobalt oxide and nickel cobaltite. I have found that the peak intensity of pure cobalt oxide is higher than nickel cobaltite. Is there any reason for higher XRD peak...
04 May 2015 2,094 17 View
Any one can help me how to calculate the band edges of semiconductor based on theoretical calculations. I need to calculate the the band edge positions for ZnO and CdS. Authors have reported that...
03 April 2015 3,136 6 View
I have prepared the Fe2O3@graphene nanocomposites using commercial Fe2O3 (size = 200 nm) and commercial graphene oxide (GO) via HI reduction. Afterward, I have prepared the active electrode film...
01 January 1970 3,582 4 View
Hiiiii everyone! I have an enquiry on statistical analysis. I was looking for many forum and it's still cannot solve my problem. I want to compare means of two groups of data but only with two...
03 March 2021 8,796 3 View
I am on the lookout for the Enhanced Yellow Fluorescent Protein (Aequorea victoria) DNA sequence. Does anyone know where I can find it? Thank you in advance
03 March 2021 3,568 1 View
Hi, I want to start testing pitfall trap to obtain ants samples, but I need to conduct molecular analysis on those insects. So, what kind of fluid can I use? Ethanol expires too early and I need...
03 March 2021 5,978 5 View
What's the best way to measure growth rates in House sparrow chicks from day 2 to day 10? Since, the growth curve from day 2 to 10 won't be like the "Logistic curve" it might not follow logistic...
03 March 2021 1,401 3 View
Hi, I am after the reference below, my library says it cannot obtain a copy either locally or internationally, any help appreciated! Chris Wang ZM, Heshka S, Wielopolski L, Pi-Sunyer FX, Pierson...
03 March 2021 6,193 1 View
i am try to classify the x-ray images. During classification , can i block unwanted images (except x-ray image).
03 March 2021 7,100 1 View
I have conducted and published a systematic review and meta-analysis research with the topic related to public health and health pomotion (protocol was registed in PROSPERO). Now we want to...
03 March 2021 8,920 3 View
dear community, my model is based feature extraction from non stationary signals using discrete Wavelet Transform and then using statistical features then machine learning classifiers in order to...
03 March 2021 6,994 5 View
I just wanted to check if I need to run a linear regression separately if I am using PROCESS MACRO to run mediation analysis. Thank you.
02 March 2021 4,359 3 View
If the detection range is in ng/ml but the reference range is in ug/ml for a molecule or protein in serum or plasma .how to dilute and what is the initial volume to be taken for quantitative analysis
02 March 2021 7,670 3 View