I made a graphene suspension after sonicating synthetic graphite powder in DI water ( 100 mg graphite powder in 100 mL in DI) for 1 h. Can I oven dry it prior to the BET analysis?
Thank you
Freeze drying the sample should help you to avoid re-stacking of the platelets.
After this, you should heat up to some 150 degC at high vacuum for degassing.
Hi;
The sample should be lyophilized. You should also degas your sample for at least 16 h at a low temperature so as not to alter your sample.
With my best regards
I am an undergraduate student at the University of Peradeniya Sri Lanka, currently working on ecto-parasites in domesticated animals. I found difficulties in the identification due to a lack of a...
15 February 2021 277 1 View
I need to know the computing requirements to do SAR time series analysis and how many SAR rasters (images) should be analyzed?
17 September 2020 9,281 1 View
I made a graphene suspension ( 100 mg in 100 mL DI water) by sonicating synthetic graphite powder (BET surface area= 10 m2/g ) for 1 h. After the sonication, the graphite BET was 8 m2/g. I...
24 January 2020 6,881 3 View
Insects have been consumed by human diet since prehistoric times. At present, the idea of looking at insects as food has been getting traction worldwide, also in response to increasing food...
03 March 2021 6,223 5 View
Hello, I would like to ask how to grow E.coli which resists 50 or 100ug/ml of Blasticidin. I have tried many methods by using low salt Luria-Bertain(LB) agar plate. However, no colonies grow. Let...
01 March 2021 2,027 2 View
In the stabilization of AgNPs are vital in current research interest. However, some of the 2D nano-materials like graphene oxide, MoS2, etc... previously used to stabilize it. But still they shown...
01 March 2021 2,207 3 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
Hello everyone, I'm looking for a way to delaminate copper current collector of water-based anodes in Li-ion batteries without damaging the graphite film. I tried different materials such as HNO3...
24 February 2021 3,785 3 View
I am trying to reduce graphene oxide by thermally but I have no proper information regarding this. Can any one help me regarding the details about temperature and time for the reduction of...
23 February 2021 4,155 4 View
As a beginner in electrochemistry, I tried to obtain cyclic voltamograms of commercial anatase powder deposited on an ITO substrate or on Eteck. After several attempts, I noticed that my cyclic...
23 February 2021 3,175 3 View
I am working on synthesizing and then purifying peptides using the SPPS system. After purification of the peptide, the peptide powder is obtained using a freeze dryer. When measuring the powder,...
22 February 2021 10,099 5 View
My main concern is that the metal powders should not weld to the mold surface and I should easily be able to eject out the pressed samples. I am looking for alternative for graphite moulds. The...
22 February 2021 2,965 4 View
I performed a Proton NMR of graphene powder prepared by electrochemical exfoliation technique. It shows some peaks. But I can't understand it.
21 February 2021 8,947 3 View