I want to eliminate the electrostatic effect between the tip and the sample by applying DC voltage to the bottom electrode and then performing Piezoresponse microscopy. How can I do this in PFM mode, I am using Nanoscope Software. TIA
If we have already designed a model in cstmws, how can we make equivalent circuits from it?
12 December 2023 626 0 View
I am working on Energy storage devices.
04 August 2023 4,946 0 View
Can anyone suggest something to resolve the issue of distorted friction images on the AFM? We tried several things: switching off the system and computer, reconnecting wires, changing tip, scan...
30 July 2023 2,927 11 View
I am trying to do a potential energy scan of a BTA (N,N',N''-trismethyl-benzene-1,3,5-tricarboxamide) dimer. I defined the coordinates of the COM (I choose 6 carbons of benzene ring for this)...
30 April 2023 557 0 View
I am trying to prepare Indigo using Baeyer–Drewson method. However, the NMR spectrum in DMSO shows the presence of a side product along with Indigo. How can i purify the material
06 October 2022 3,173 4 View
I am trying to do some photochemistry with porphyrin derivatives.
14 September 2022 7,078 2 View
I have tried around 4 journals but no one accepted my paper and they remarked "manuscript was not suitable for the journal" with no suggestions. Therefore, I am confused so where to publish my...
21 December 2021 7,882 3 View
Focusing on dissolution studies of drugs, if a buffer was made with a pH of 6.8 with a temperature of 25'C and than transferred to a Vessel of whose the temperature is 37'C, won't the buffering...
23 July 2021 6,418 3 View
My research topic is "Social Responsible Investments In India". I need to construct midcap and largecap index from NSE ESG index and other indexes for my research. can i get detailed explaination...
09 June 2019 3,204 4 View
I am trying to prepare amine functionalized porphyrin and proton nmr shows some weird shift. Is it due to intermolecular interaction ?
15 January 2019 2,908 3 View
I have virus (viral hemorrhagic septicemia virus) in suspension and the experiment will not involve cells. What level of TCID50 is preferred?
11 August 2024 3,115 1 View
Let's say we have a standard, regular hexagonal honeycomb with a 3-arm primitive unit cell (something like the figure attached; the figure is only representative and not drawn to scale). The...
07 August 2024 1,937 1 View
Hello dear colleagues, We have prepared a manuscript on NiTi-based alloys and are seeking a second opinion on our current TEM results. If you are a Ph.D. holder with experience in TEM and have...
07 August 2024 9,563 0 View
After immunohistochemistry of previously fixed in PFA and EtOH and then frozen 20 μm sections of zebrafish brain, DAPI staining is very weak (right) compared to the same sections stained without...
05 August 2024 9,637 2 View
average particle size calculation from TEM
04 August 2024 2,921 1 View
I am working on a SEM model where i have 7 latent variables (6 exogenous and 1 endogenous). In AMOS when I co-vary the exogenous constructs, only 2 paths are coming significant out of 6. But when...
03 August 2024 6,028 4 View
I am using a Bruker 600M solid-state NMR spectrometer with a Micro 2.5 microimaging system. The test sample is a tube of 1M LiCl aqueous solution, and the nucleus detected is 1H. I am trying to...
01 August 2024 9,227 1 View
I've seen articles that primarily focus on alpha and beta activity in the frontal regions, but these studies often compare healthy subjects with those having various pathologies. I haven't seen a...
31 July 2024 7,259 1 View
Suppose I am studying the construct of "Academic Motivation" (latent variable) in students, which is measured through three observed variables: "Intrinsic Motivation," "Extrinsic Motivation," and...
31 July 2024 3,913 6 View
i am working on ischemic stroke. for immunoflourescence i want to use zeiss confocal microscope.before i used VS120 but the images from vs120 not so good now i want to use zeiss confocal but i...
30 July 2024 2,349 1 View