I am working on a 25kw T-type 3-level inverter
Two reference sine wave (one shifted with a dc value) can be compared with a common triangular wave to obtain PWM signals for 3 level inverter. Vice versa is also possible. common sine wave compared with shifted triangular wave
Dear Ranjith
kindly refer the ieee paper given below.
Neutral-point voltage balancing control for three-level T-type inverter using SHEPWM
Than you very much for your answers
Hi,
Find the following paper and its references
Model Predictive Current Control of a Three-Phase T - Type NPC Inverter to Reduce Common Mode Voltage
http://www.worldscientific.com/doi/abs/10.1142/S0218126618500287
After measuring VT curve using Electro-optical Characteristics Measurement System like LCMS, how to plot graph. What is PD voltage and relative transmitance. Is the VT curve means graph between...
15 May 2024 2,393 0 View
I would like to do genome assembly for the bacteria isolate from the environment. Can any provide me the information or any tutorial? It would be helpful! thanks!
18 April 2024 1,894 12 View
Greetings to all, As part of my research, I am synthesising carbon quantum dots. Using ethanol as the solvent, I performed a solvothermal method. As I have tried different temperatures and times...
06 February 2024 1,459 3 View
I did 10 cycles of charging and discharging at a fixed current (Chrono galvanostatic) with Metrohm Autolab for my material that is being tested as supercapacitor. I wanted to export the data from...
15 November 2023 2,071 1 View
I am looking for VEGF A expression in mice placental lysates. However, according to the company (I use primary antibody from Abcam), I was supposed to see band 27kDa, however, I see 37kDa. They...
16 October 2023 7,283 3 View
need a brief answer wrt the question mentioned above
03 October 2023 3,010 2 View
I synthesized CQD and when measure the PL intensity using the fluorescence spectra, I got good intensity value and peak position in green region. I measured PL intensity using sample taken in...
10 July 2023 6,580 1 View
After synthesizing CQD using solvothermal method, if it is treating again with temperature during any purification step(lower temperature compared to synthesize temperature) is that chances for...
04 July 2023 9,695 0 View
I have checked with all parameter files but SOD parameters are not present in any of the parameter file. Can someone help me with this query !
26 March 2023 8,437 0 View
I have phenol crystals and Tris crystals, so how to prepare Tris Saturated phenol for DNA isolation. (and also share there pH and temp conditions to store). After preparation phenol, how prepare...
01 November 2021 1,240 2 View
I am using a Bruker 600M solid-state NMR spectrometer with a Micro 2.5 microimaging system. The test sample is a tube of 1M LiCl aqueous solution, and the nucleus detected is 1H. I am trying to...
01 August 2024 9,227 1 View
Hello!!! I want to implement the Swerling characteristics functions (CF) directly in MATLAB without using its Fourier integral pairs...the Swerling CFs are actually Laplace Transform of the signal...
23 July 2024 4,925 1 View
I'm currently working on the implementation of pulses (legumes) in bakery applications. In one case, pulse flours could be added to bread to increase the nutritional value. Pulses (in particular...
17 July 2024 7,293 3 View
According to various research, soybean is not considered a pulse because of its high fat content.
30 June 2024 6,311 0 View
I am attempting to determine which current inputs (in uA) are subthreshold for inducing a burst of activity. This is because I am attempting to model DBS form epilepsy in vitro, which clinically...
23 June 2024 4,083 1 View
I'm a graduate student at UWM focusing on electrophysiology. I'm trying to perform Shaffer Collateral stimulation of CA1 pyramidal neurons. If I were to have a protocol with 6s of no stim, 2...
18 June 2024 319 0 View
I recently measured the very high capacitive current in solar modules (Usually very small, i.e., in mA). 2 devices were burned during the measurements. Can anybody explain the reason for a such...
05 June 2024 4,489 0 View
How can someone remove different artefacts leading to false results due to electrostatic and flexoelectric effects during PFM measurements? during measurement what steps can be taken to nullify...
02 June 2024 8,242 0 View
Hello, Could some one help me by recommending papers or books that handle modelling and control 6-switches 3-phase PFC, i.e. state space or tranfer function models, and various control techniques...
29 May 2024 9,407 0 View
In DBS settings, I have seen stimulus widths of up to 500 us in duration; however, the most common pulse duration seems to be between 90-150 us. Clinically, mono- or bi-polar electrodes can be...
26 May 2024 5,819 0 View