You should check if the scf criteria for g98 and g09 are same or not. In your input you have assigned multiplicity 2, but you are using restricted but I think you should use unrestricted. scfcyc should be changed to scfcycles. If you do not need raman, you can write freq=noraman. Also when you want to have check point file, you should write %chk=opt.chk according to the size of your molecule 8 or 12 cores are enough.
You should correct the multiplicity. It is “1”, not “2” for the anion as Mr. Yourdkhani has pointed out. The difference of the thermochemistry is “0” between the data by G09 and G98 (below). Or the confidence level is r2 = 1.000 (standard deviation SD = 0), meaning a 100 % reliability of the energetics. Towards Q-data, r2 = 1 (100 %), SDs within ca. 1.E-4 to 1.E-7 (statistics by rows); P < 0.0001 and SD ca. 1.E-5 (linear approximation) (attachment).
Gaussian-98
%Chk=Untitled-1.chk
Default route: MaxDisk=2000MB
-------------------------------------------------
#p b3lyp/6-31+g(d,p) opt=(calcfc) freq scfcyc=200
-------------------------------------------------
1/10=4,14=-1,18=20,26=3,38=1/1,3;
2/9=110,17=6,18=5/2;
3/5=1,6=6,7=111,11=2,25=1,30=1/1,2,3;
4//1;
5/5=2,7=200,38=4,42=-5/2;
8/6=4,11=11,23=2,27=262144000/1;
11/6=1,8=1,9=11,15=111,16=11/1,2,10;
10/6=1,7=6/2;
6/7=2,8=2,9=2,10=2,28=1/1;
7/10=1,18=20,25=1/1,2,3,16;
1/10=4,14=-1,18=20/3(1);
99//99;
2/9=110/2;
3/5=1,6=6,7=111,11=2,25=1,30=1/1,2,3;
4/5=5,16=2/1;
5/5=2,7=200,38=4,42=-5/2;
7//1,2,3,16;
1/14=-1,18=20/3(-5);
2/9=110/2;
6/7=2,8=2,9=2,10=2,19=2,28=1/1;
99/9=1/99;
Leave Link 1 at Sat Sep 17 12:36:34 2016, MaxMem= 0 cpu: 0.0
(Enter C:\G98W\l101.exe)
----------
Untitled-1
----------
Symbolic Z-matrix:
Charge = -1 Multiplicity = 1
C 0 0.21378 0.12248 -0.00205
O 0 0.87753 1.17235 -0.00572
O 0 0.90726 -1.19138 -0.00562
H 0 -0.89862 0.16322 0.00385
Leave Link 101 at Sat Sep 17 12:36:34 2016, MaxMem= 6291456 cpu: 0.0
You do not need new outputs, because of there are already shown. You have available the corresponding Z-matrix and route sections. These data you can prepare as new inputs in *.txt format and to run them by 98 and 09, independently.