I have already tested several forms of purification to obtain the monomer AB peptide, all of which have failed, it has aggregated quickly, I only obtain oligomers.
Are you producing recombinant AB. We buy synthetic peptide an resuspended in 100% HFIP to 1mg/mL and the aliquot. Store those at -80 degrees until further use. Before our assays we just open the lid of the tubes to get HFIP evaporated and then resuspend it in buffer (PBS 7.4)