Does anyone know of a supply of reusable cytospin funnels? We have an old, but working Shandon 59900109 cytospin 2 and someone cleaned our funnels with alcohol and a strong detergent. Our last 12 were purchased used on ebay.
Hi, I hope that someone can help me with this task: I have 5 groups of participants which are numbered in SPSS from 1 to 5 (according to their group number) and are all under the variable group....
03 March 2021 506 3 View
Hi all, Can cells be reused after I have seed them onto 96 well plates and test them with cell counting kit at OD450 (CCK8) at 12 hours, wash them with PBS x3 and add new media and let them...
24 February 2021 5,072 1 View
I want to know how to change the status of an article.
21 February 2021 1,536 2 View
I'm looking to biotinylate a protein that precipitates in PBS. The recommended reconstitution buffer for the protein is urea/Tris buffer, pH 7,5 (7 M urea, 5 mM EDTA, 15 mM mercaptoethanol, 20 mM...
04 January 2021 7,681 5 View
Hello, we are currently working on absolute quantification with SYBR Green qPCR. We excised from a plasmid containing the cDNA, a fragment, which will be amplified by the primers we used in our...
10 November 2020 769 4 View
Hi all, I'm doing a bunch of Cell Titre Glo assays to assess the effects of several inhibitors on 2 cell lines. Problem is, for some of the wells they seem to be luminescing less than the...
30 October 2020 1,513 2 View
I am looking for a reliable and sensitive AMH ELISA for use with rat serum (and potentially plasma). Recommendations are welcomed! Thank you in advance.
08 July 2020 3,207 2 View
" Picture a world where every product and appliance is environmentally friendly, where every supermarket item is fair trade, where corruption is an urban myth and poverty a long-distant memory....
19 May 2020 1,933 3 View
Hello, I am interested in this research field. I have the prototype of my microfluidic chips, but I am having a hard time finding literature that says exactly how they incubate their chips (with...
21 April 2020 3,277 5 View
I'm doing a meta-analysis on prognostic studies. The studies I have included present the following values: AUC, 95% CI, a cut-off value and associated sensitivity and specificity. Also, is it...
01 March 2020 10,001 2 View
Excessive rotation of nodes in node set ErrNodeExcessRotation-Step1
17 August 2021 0 0 View
20 June 2021 0 0 View
--> FOAM FATAL ERROR: Maximum number of iterations exceeded From function Foam::scalar Foam::species::thermo::T(Foam::scalar, Foam::scalar, Foam::scalar, Foam::scalar (Foam::species::thermo::*)(Foam::scalar, Foam::scalar) const, Foam::scalar (Foam::species::thermo::*)(Foam::scalar, Foam::scalar) const, Foam::scalar (Foam::species::thermo::*)(Foam::scalar) const) const [with Thermo = Foam::hConstThermo >; Type = Foam::sensibleEnthalpy; Foam::scalar = double; Foam::species::thermo = Foam::species::thermo >, Foam::sensibleEnthalpy>] in file /home/ubuntu/OpenFOAM/OpenFOAM-4.1/src/thermophysicalModels/specie/lnInclude/thermoI.H at line 66. FOAM aborting #0 Foam::error::printStack(Foam::Ostream&) at ??:? #1 Foam::error::abort() at ??:? #2 Foam::heRhoThermo >, Foam::sensibleEnthalpy> > > >::calculate() at ??:? #3 Foam::heRhoThermo >, Foam::sensibleEnthalpy> > > >::correct() at ??:? #4 ? at ??:? #5 __libc_start_main in "/lib/x86_64-linux-gnu/libc.so.6" #6 ? at ??:?
24 March 2021 0 0 View
What's the best way to measure growth rates in House sparrow chicks from day 2 to day 10? Since, the growth curve from day 2 to 10 won't be like the "Logistic curve" it might not follow logistic...
03 March 2021 1,401 3 View
I looking for ferro calcium production process
03 March 2021 1,755 4 View
Hello, good day! I am trying to simulate similar bimorph piezoelectric harvester with below commands. However, the output power doesn't change with resistor value. Please help to find the reason. ET,10,CIRCU94,0 !SET UP RESISTOR R,1,100000 !RESISTANCE VALUE TYPE,10 !SET ELEMENT TYPE E,1,2 !CREATE RESISTOR BETWEEN NODES 1 AND 2 Thanks in advance Regards,
02 March 2021 0 0 View
I would like to research on MR images (0.5T and 3T). Can you please suggest some websites that I can download dataset including both 0.5T and 3T MR images? Thank you.
02 March 2021 7,735 3 View
Which is suitable for use with Python? MySQL or SQL Server? What is your suggestion?
01 March 2021 3,422 3 View
I like to do project in laser measurement system. My objective is to eliminate or reduce the cosine error, abbe error in Laser measurement system. I have Rhenishaw XL80 system. Please tell the...
28 February 2021 4,890 3 View