I need to extract Phospholipids from TLC plates by scraping out the requisite spot from the plates. Could anyone suggest an appropriate solvent to re-suspend the extracted phospholipids to use for later purpose??
5-10% MeOH-DCM or higher depending on compound's polarity.
You can try with mixtures of chloroform and acetone depending on the phospholipids nature.
could u suggest any reference paper for the same???
Instead of checking only the mRNA level, I want to check the active protein level of MMP-1 in Liver tissue from mice. How can I do that?
03 March 2021 1,763 2 View
I want to analyses the proportion of swimming sperm of three species of fish in two salinities. To analyse the proportion of swimming sperm in a Generalized Linear Model, I would use a Binary...
03 March 2021 2,297 3 View
03 March 2021 8,272 1 View
Hi. Please tell me what guidelines should i need to follow for questionaries' type research work in India. It is not hospital based work, we are conduction basic institutional based qualitative...
03 March 2021 2,037 3 View
Hi, I implemented a code to gabor filter cifar10 data but the images after being filtered and stacked are not clear like the original images. I think the problem is in the way I am using the...
03 March 2021 6,317 1 View
i am try to classify the x-ray images. During classification , can i block unwanted images (except x-ray image).
03 March 2021 7,100 1 View
03 March 2021 5,360 2 View
The term miscibility refers to the single-phase state in thermodynamics. I do not mean the compatibility of different components. To determine the miscibility I know several techniques such as...
03 March 2021 4,107 4 View
If the detection range is in ng/ml but the reference range is in ug/ml for a molecule or protein in serum or plasma .how to dilute and what is the initial volume to be taken for quantitative analysis
02 March 2021 7,670 3 View
02 March 2021 5,204 3 View
I am using a 2707 waters HPLC device. When I try to inject a sample, it says missing plate or rack. I changed the needle and calibrated its position but I still get the same problem. I even get...
02 March 2021 1,408 1 View
Hello! I'll do a size exclusion chromatography, but I only have an open column, and I'll perform the peptide extraction from yeast, using buffer lysis (sodium phosphate 50 mM/NaCl 30 mM/DNAse and...
01 March 2021 2,215 2 View
Hi, I am running a size exclusion chromatography experiment with a buffer containing Potassium Acetate as a salt. I analyse these fractions through SDS-PAGE. After boiling my SEC fractions in...
01 March 2021 2,622 3 View
I am doing my thesis on the nutrient deprivation on the macroalgae Rhizoclonium sp. I will be analysing the levels over a period of roughly 5 days by HPLC-UV and GC/MS. I will be using seawater as...
28 February 2021 6,477 1 View
Favourable conditions of base pressure, rate of deposition. Also, by which characterisation technique to be used to verify the thickness of the deposited film.
28 February 2021 3,640 3 View
We have always used the 96 welled plate, the 48 welled plate but apparently there is much evidence on the 24 welled plate and above all its benefits.It states it is the same you would use on ELISA...
28 February 2021 1,149 1 View
I am using the concept of plant functional traits (Cornellisen et al., 2003) in a paper. Considering descriptions for whole plant traits (life history; life form; growth form; plant height;...
24 February 2021 6,831 5 View
Hi, I am a chemistry undergraduate doing my dissertation project on HPLC. In my project, I need to predict the HPLC retention time of 20 aromatic molecules, the calibration set. To do this I will...
24 February 2021 2,602 1 View
24 February 2021 2,362 5 View
As it is highly probable that pellets will have a higher degree of air gaps and voids than thin films, is it possible to pole the samples with corona poling nevertheless? Or is there the...
24 February 2021 1,349 1 View