The sample contains Si, O, Fe, maybe H in its chemical composition. It is poorly crystallined. Its XRD pattern and raw data is attached below. Could anyone help me to interpret it.
Thanks in advance!
Can't find anything fitting with this composiyion. Are you sure theseare the only elements in your compound?
Thank you very much, Muhamad and Natale.
@Muhamad, The presence of nanosized particle is confirmed by TEM, but I want to identify what mineral phases it contains. Could you help me with this?
@Natale,This material is synthesized with FeCl3, NaOH and tetraethyl orthosilicate. Therefore, Na may be also present.
Best wishes,
Peixin
It is akaganeite, see attached files
Yes, it is akaganeite. Thank you so much for your kind help, Natale.
Regards
Pestle of a agate mortar in my lab has broken, can I use another one which has a little different shape? In other word, must a agate mortar only be used with its matched pestle and ones with the...
09 October 2016 8,510 3 View
Could anyone please tell me the CAS number of the reagent R(OCH2CH2)7O(CH2)3SO3-K+ (R: C13-C15 alkyl chain) or tell me where I can purchase this reagent? Thanks in advence.Best regards,Peixin Du
31 December 2015 2,324 7 View
Our research group has a Bruker D8 Advance X-ray diffractometer, the clay minerals (the sample) to fill the holder is near 0.7g, but one of my samples is only 0.2g, how to do the XRD analysis and...
07 August 2015 5,634 18 View
Recently, i want to study the stability of kaolinite in acid and alkine solution. How to measure the concentration of Al and Si in solution?
02 March 2015 1,129 7 View
i am unable to interpret why its increases in start as shown in figure
11 August 2024 2,179 1 View
Require for Rietveld refinement in XRD.
08 August 2024 3,081 2 View
During low-temperature testing, new diffraction peaks that appear could be indicative of several phenomena. In one of our tests, we observed notable new peaks around 40° and 45° in a specific...
06 August 2024 726 3 View
I want to refine one XRD peak of my in-situ xrd but the background is never working good which ultimately fails the refinement. How to refine and adjust the background using GSAS-II
05 August 2024 5,291 2 View
How can I interpret the data gathered without solving?
03 August 2024 9,054 3 View
How to calculate the molar proportions of the oxides from the XRF analyses?
02 August 2024 2,565 2 View
I fabricated Ti3C2Tx using concentrated HF 40%, I plot an XRD as attached image below.. please let to know if I obtained it or not.
02 August 2024 6,789 4 View
What information we can get from PXRD analysis other than from SCXRD analysis of a crystal ?
30 July 2024 6,261 4 View
I have multiple small samples of grass pollen with anthers. I want to find a method to identify concentrations of proteins, lipids, and other various elements for these samples. any suggestions?
28 July 2024 5,331 1 View
I will be doing an XRD on a sample which is powdered in natured and is a hydrogenated compound. I would like to know how we can understand the individual components and components by using the...
28 July 2024 4,548 2 View