Hi all,
I have a 2% stock solution of aluminium sulphate prepared as my coagulant. I tried to add 0.2mL and 2mL of coagulant to 100mL of wastewater which gives a dose rate of 40mg/L and 400mg/L. Both did not work.
All the experiments were done with fast stirring of 30 seconds and slow mixing of 5 minutes while allowing 30 minutes for it to settle.
Below are some specification of my wastewater:
COD: 13,640 mg/L
TS: 1.48%
TP: 120mg/L
NH3-N: 2658 mg/L
Just wondering if there were something wrong with my experimental procedure or dosage.