Are S-H and N-H strechings ------both possible?
If you observed C=S that time you will observe N-H band in IR. otherwise C=N & S-H bands in IR. both also possible.
Thank you sir
actually you can see the attached picture FT-IR for 2-mercaptobenzothiazole .
I have performed the optimization of pH ranging from 2-9 so that I can choose one pH value for subsequent experiments but the results pertaining to pH values from 3-9 are almost near.How do I...
02 March 2016 9,287 5 View
Attached file
01 February 2016 7,368 0 View
The adsorption of Pd(II) onto graphene oxide shows optimum pH at 6.0, whereas GO with quaternary ammonium salt shows optimum pH around 3-4. Attachment for graphene oxide on Pd(II)
31 December 2015 4,204 4 View
The results are satisfied as per EDX as it is not giving Br peak. But XPS is showing 0.55% of Br....
11 December 2015 3,506 5 View
What does the increased/decreased intensity of ID/IG imply?
11 December 2015 1,730 2 View
In interference studies to check the extraction of Pd(II), will the metal ions such as Hg(II) and Pt interfere along with Pd(II)? If yes/no. Why?
11 December 2015 1,416 1 View
If i have found the concentration of the metal ion in the filterate . Now i want to check that how much % of the metal ion is recovered.
11 December 2015 8,862 3 View
In interference studies to check the extraction of Pd(II), will the metal ions such as Hg(II) and Pt interfere along with Pd(II)?
11 December 2015 947 1 View
AIC is a statistical methodology to compare the isotherm models
11 December 2015 6,376 6 View
Actually I recovered palladium from a catalyst Pd/AC + 4HCl (aq) + H2O2 (aq) → H2PdCl4 (aq) + AC + 2H2O (i)l Now I wanted to know that whether as such I can use these palladium species for...
10 November 2014 3,961 3 View
Do these peaks in the curve indicate primer dimer or non-specific products?
01 August 2024 7,466 0 View
Hi everyone, I'd like to better separate two close peaks coming from a bioconversion sample, I'm currently using a C18 KromaPhase 4,6mm Ø.I. SCHARLAU, particle size (µm): 10, pore size (Å): 100,...
30 July 2024 435 3 View
Can we conduct DFT studies for Ionic Liquids with Amines at various concentrations? If so, how can we proceed with these studies? Additionally, what parameters, besides IR, NMR, and HOMO-LUMO, can...
18 July 2024 319 1 View
I do not know much about FTIR! The material Benzethonium Chloride USP was compared to a reference standard in regards to FTIR, as per the USP testing: Identification B. Infrared absorption (FTIR),...
16 July 2024 6,918 7 View
During the release test of Amphotericin B using 1% Tween 80, i observed three peaks even in the standard. The first peak consistently yielded results around 500%, while the other peaks showed...
08 July 2024 1,330 0 View
I synthesized some paramagnetic cobalt and nickel complexes (expected to be Co(II) and Ni(II)) using a bidentate ligand - N of pyridine ring (aromatic) and O of P=O (aliphatic), and I obtained...
03 July 2024 3,410 4 View
I isolated a mixture of three compounds from the stem bark of a plant . I have NMR, Mass spec, IR, and UV data. There are a lot of things I can't make meaning out of. Kindly help me with the...
02 July 2024 9,531 4 View
I'm trying to fitting Cu Auger peak into various state (Cu0, Cu+, CuI etc..) In Cu0, one of the peak's FWHM is 0.84 but when I try to enter smaller value than 0.89, "input error" is occured. How...
02 July 2024 4,932 3 View
Hello I have prepared metal nanoparticles and did zeta potential. Normally there is a single peak in sample but now there are 3 peaks. I prepared sample for analysis first I prepared 10 mg/mL...
30 June 2024 1,063 4 View
Hello everyone, I'm facing an issue with EDS software that prevents me from obtaining atomic or weight percentages for my scan. However, I do have access to the raw data, which shows intensity vs....
29 June 2024 6,664 14 View