I have done reitveld refinement of my material using MAUD, and getting the image of the refined XRD, I also want to extract its data points as well. Is it possible to get these data points in MAUD software? Kindly help me in this.
Why knockouts for same genes from two different gRNA are showing different result? I followed CRISPR-CAS9 gene editing technology.
25 July 2024 8,313 1 View
While doing AST for Pseudomonas aeruginosa, after incubation, no zone of inhibition observed in the plate near the well. wells surrounded by bacterial growth, when the same plate observed under UV...
25 July 2024 9,229 1 View
How to calculate percentage cumulative drug release when, Total volume of dissolution media = 250ml Added formulation was equivalent to 10mg of drug Sample withdrawn = 1ml each time Sink condition...
15 July 2024 4,192 1 View
Is it necessary to add stop solution in Elisa plate?
30 June 2024 8,235 2 View
Hello! I am facing a problem, I tried using pdb2gmx to generate topology file but it shows error HEA residue not found then I tried copying the forcefield file and edited accordingly but again...
24 June 2024 1,242 0 View
We are willing to make notice of Miller indices present in XRD powder and managed as their JCPDS files. We need them for various substances, e.g. Graphite, copper, lithium, and Iron. Kindly share...
23 June 2024 864 2 View
After Plagiarism checking in Turnitin, the result shows that the similarity of my manuscript is from ''Article with reviewer- feedback from Springernature'' and the link provided opens a word file...
20 June 2024 8,325 1 View
I have tried to screen various phytochemicals of different plants leaves sample with antimicrobial property. I have tried aqueous extract of plants. But i have doubt whether sample is actually...
18 June 2024 8,947 4 View
I am planning to do invitro transcription and capping for an mRNA vaccine generation. Can anyone suggest whether it should be done on a bench top or inside a laminar hood?
14 May 2024 186 3 View
How can we use Ovito to do this. I have deformation behavior results from MD simulation under uniaxial tension and I want to see misorientation .
01 May 2024 7,211 0 View
Require for Rietveld refinement in XRD.
08 August 2024 3,081 2 View
I want to refine one XRD peak of my in-situ xrd but the background is never working good which ultimately fails the refinement. How to refine and adjust the background using GSAS-II
05 August 2024 5,291 2 View
I have incorporated the dispersion effect for the OPBE functional by specifying the S6, SR6 and S8 parameters for GD3 in Gaussian G09 package. For this purpose, I have defined the environment...
05 August 2024 1,494 2 View
One of the papers I read by Toby, where (title of the paper was "R factors in Rietveld analysis: How good is good enough?"), he tells us that to get good chi square value, you must have low Rwp,...
17 July 2024 9,668 4 View
I forgot to autozero during the run (Size exclusion chromatography.) and later i realised i forgot to do that and the baseline was not zero but below zero (and in some cases it above zero). I...
15 July 2024 5,551 6 View
here's a concise guide for preparing your CSV dataset in Excel to identify flood-triggering factors using an ANN: Clean and Format:Address missing values (fill with mean/median or remove if...
21 June 2024 7,941 0 View
Hello everyone, i have hyperspectral dataset recorded on a hyperion (Bruker), in opus file (.#). I would like to send the data to matlab, but i am lost... I just managed to export one spectrum via...
20 June 2024 3,412 0 View
I am trying to refine my data in full prof and my chi2 is 0,834E11 and everytime i try to refine the data the plot deviates further from the actual data and the chi2 doesnt change. The first image...
02 June 2024 5,805 5 View
Sample displacement in microns is found under the "Sample Parameters" item in the menu tree. Should this be refined at all during Le Bail refinement?
02 June 2024 663 0 View
Chi-squared is a small, good-fit chart but it has high R factors. Is this result acceptable?
25 May 2024 6,830 0 View