11 November 2014 4 6K Report

Dear researchers,

Experimental investigations are to be carried out on a prototype to determine the design stress levels.

Prototype : Chamber filled with SF6 gas. Conductor running longitudinally and isolated from the tank/chamber by the gas.

Objective: Determine the withstand voltage level with 50% probability through experimentation and establish the 90% withstand voltage level theoretically.

Reason : In up-down method of stressing the insulation, only 1 shot per group is to be applied and there is no mention in the IEC 60060-1 to determine the 90% withstand voltage level.

We know that the breakdown characteristics of SF6 follows weibull distribution. Could I determine the 50% withstand voltage level and extrapolate through curve fitting to obtain 90% withstand voltage level?

If yes, how do I  proceed after establishing 50% withstand voltage level? How to determine the maximum likelihood estimator and how is it helpful in this regard?

Thank you