14 Questions 10 Answers 0 Followers
Questions related from Tasneem Harahsheh
i have carbon screen printed electrode and gold nano particles suspension in citrate buffer, how to deposit the particles on the electrode in a way to get uniform distribution?
01 March 2019 9,495 3 View
i have amino acid sequence of protein and I am looking for a free tool can predict the 3d structure, also i have the aptamer of this protein and i want to know how they bind with each other ?
17 February 2019 5,479 5 View
hello all , in my lab i have PGZ100( EIS Maximum frequency 100 kHz , Best current resolution 30 pA, Scan rate 0.5 V/s , Lowest current range 1 µA , Frequencies/decade 5,10,15) does this...
03 January 2019 9,262 9 View
hello all in my lab i have NI ELVIS ( which includes an oscilloscope, digital multimeter, function generator, variable power supply, Bode analyzer, and other common lab instruments. You can...
21 December 2018 327 2 View
i want to design IPMC actuator with fast bending, membrane selection and antiparticles how affect the actuator response and what parameter responsible to provide fast actuation?
04 December 2018 241 2 View
hello, i am working on designing a smart soft robot, the robot will perform linear movement, i have no idea how to use IPMC as a self sensing linear actuator. if any one have an idea regard self...
30 November 2018 8,218 3 View
Currently Iam working on amperometric biosensor using SPCE (screen printed carbon electrode) but I still confuse to figure out what is the different between this electrode with Interdigitated...
05 November 2018 7,851 2 View
hello, iam working on an electrochemical sensor, to detect protein biomarker using DNA prob, i want to design a read out circuit for my sensor, also i want to know what is the differantce between...
04 November 2018 2,866 2 View
is there any publish research show the salivary biomarkers concentration for breast cancer? iam trying to design a salivary biosensor for early detection of breast cancer. recommend me some...
27 July 2018 9,533 3 View
HER-2 is the most important biomarker for breast cancer screening, and to design electrochemical sensor , the transducer used is based on the bio-marker bio-receptor interaction, is it possible...
02 June 2018 1,145 1 View
i went to know the biomarkers level of breast cancer in saliva, if any one worked in this area ? thank you
02 February 2018 2,917 2 View
HELLO any hint to derive the close form solution of the robot in the following picture??
15 December 2017 1,659 6 View
let we have frame A and frame B, then we rotate the frame system by theta, around vector K which is the axis of a finite rotation, how to derive the rotation matrix of frame A with respect to...
21 October 2017 1,346 1 View
i need ECG signal for sleep apnea, heart failure and atrial fibrillation ....
28 May 2017 141 5 View