7 Questions 1 Answers 0 Followers
Questions related from Musa Ibne Mannan
I keep getting this kind of CV and DPV curves. The DPV does seem like having a plateau instead of a smooth peak. (1) What could be the cause of this? (2) If I use the DPV peak to compare...
29 April 2023 2,573 0 View
I designed a aptasensor for tRF detection. I need to know what could be the usual practice for tRF concentration range to have a convincing application for plasma tRF detection? I need to...
01 March 2023 9,091 1 View
I was testing a sensor, and conducted electrolysis for different NaCl concentration (which is irrelevant) but ever since I think my Ag electrode became Ag/AgCl because the CV diagram is giving me...
20 October 2022 2,038 1 View
I printed my 3-electrode system's electrodes with an inkjet printer. Now I have Ag electrodes but I need to convert it as Ag|AgCl. We are running low on budget so I have been looking for the...
08 September 2022 4,803 0 View
Hi, I am looking for DuPont™ Kapton® FPC substrate that can withhold 400°C or a little more in the USA. I googled and found some sources, however, I would love to hear from you, if you have any...
08 August 2022 7,618 0 View
From my understanding, we can directly print AgCl on PI sheets or some other substrates now, so can we directly use AgCl as a 3-electrode system reference electrode. If we directly use AgCl as...
14 March 2022 302 3 View
I intend to work on a 3-electrode system in microscale. I need to understand the benefits for AgCl in Reference Electrode than other materials.
22 November 2021 8,663 4 View