Since in z-scan experiment intensity that people normally refer is in Gw/Cm2 i want to know how to maintain such a high intensity and can some body suggest how to calculate it during the experiment.
Dear Aamir Mushtaq,
You must use pulsed laser. And to calculate intensity, you only measure beam radius.Note that Z-scan range from 5z0 to -5 z0.
In 2-D bilayer indirect band gap material with no traps is it possible to get saturable absorption behaviour when exciting with energy less then the band gap.
10 November 2017 5,248 0 View
what could be the final form of the equation how it looks like when saturable and reverse saturable absorption present in the sample at lower and higher intensities,I mean combining total...
04 May 2017 1,775 6 View
Regarding z-scan, while fitting open aperture data how can we get conformation that we are on a right track while calculating saturation intensity Is is it less then peak intensity or...
04 May 2017 160 4 View
Is it possible to achieve Electron transfer from CdSe QDs( with TOP ligand on its surface)to 2-D material in time a time domain of 45-50 ps ? What is the effect of different ligands on ET transfer...
03 April 2017 5,564 2 View
Kerr rotation measurement ?
05 June 2016 6,076 1 View
fermi surface
03 April 2016 720 1 View
fermi energy
03 April 2016 6,305 2 View
11 December 2015 3,854 15 View
Hello, I spin-cast two different polymers onto wafers and measure their height as a function of initial concentration. For polymer A, I have the weight-average molecular weight (Mw) as well as...
28 February 2021 7,882 2 View
Dear colleagues, I have found that many authors have a concern regarding their missing citation in RG because often citation in RG is lower than google scholars. I also missed some citation...
26 February 2021 928 6 View
26 February 2021 7,279 2 View
When I run the job for TS(QST3) in gaseous phase, it was completed without any error. But when I add water in CPCM model it terminated with an error: Inconsistency: ModMin= 2 Eigenvalue=...
21 February 2021 3,198 2 View
Hi all, I have a question regarding calculations using the Pfaffl method. I have 3 groups per experiment: 1 control group (calibrator) and 2 treatment groups with 6 to 7 biological repeats per...
19 February 2021 8,351 2 View
I have a 3D CT image of a car engine in raw form with no header information. When loaded into numpy array as 16 bit unsigned integer, I noticed that the values range between 0 to 52000. Is this...
15 February 2021 4,736 3 View
Hi everyone, I would really appreciate it if someone can tell me when and why a raw fluorescence starts below zero. In the picture attached below the blue colour curve starts from a negative...
09 February 2021 4,642 3 View
02 February 2021 9,574 5 View
Hi all, Is there any software or webserver to read the molecular dynamics (MD) simulation trajectory which obtained from Ab initio MD simulation to calculate the atom-atom radial distribution...
25 January 2021 9,474 3 View
I am using finite difference method to discretize the parabolic equation (explicit method), but confused about the chemical reaction term. Solving the generic equation for i specie involves a...
24 January 2021 1,149 18 View