I found many variations in literature such as p/p0, p/p0, p/po, p/po, P/P0, P/P0, P/Po, P/Po,
Is it Uppercase or lower case?
Is it alphabet "o" (again uppercase or lower case) or numerical 0 (zero)
Is it subscript or superscript?
Freundlich adsorption isotherm model fits well with the experimental data for CO2 adsorption on activated carbon (AC). Can I evaluate the thermodynamic parameters by considering ln K = n (“n” =...
02 March 2016 7,147 4 View
I have applied the Yoon-Nelson kinetic model to the experimental data obtained for CO2 adsorption on solid adsorbents. For the two materials studied, the experimental values of adsorption capacity...
09 October 2015 2,872 4 View
The raman spectrum of a sample (biomass derived carbon material) shows only two brooad peaks at about 1353 cm-1 and 1584 cm−1, assigned to D-band and G-band, respectively. The ID/IG ratio was...
06 July 2015 2,296 18 View
If a gas mixture (10% CO2 + 90 % Helium) is passed through a distilled water maintained at constant temperature of 323 K, what are partial pressure and vol% of each component (CO2, He, and...
05 June 2015 3,502 1 View
I have been getting a low plasma and no coating while doing rf sputtering of copper doped ZnS using a power of 140 watts and at pressure of 6.5x10-3 Mb.
07 August 2024 4,526 4 View
Hello, I suspect that a molecule I am using is causing bacteria to experience osmotic shock. What chemical properties should I look for to compare this capability with those of other substances?...
06 August 2024 977 1 View
My photocatalyst from solid waste red med. Dye is methylene blue My all parameter study is showing zero order. How to prove it further that the reaction in zero order?
29 July 2024 7,404 1 View
I know the difference between instrumental LOD and method LOD but my query is - in case of any sample whose concentration is zero or not detected by the instrumental LOD, is it possible to get...
24 July 2024 6,592 5 View
Currently I need to calculate detection probabilities (PD) from radar cross section (RCS) data. Beta distribution parameters for this RCS data are calculated and will be used in Swerling0...
22 July 2024 868 0 View
In cases where the rotational of the magnetic field H is zero, we can define this field as the gradient of a scalar function defined as the magnetic scalar potential (similar to the electric...
21 July 2024 9,633 4 View
Hello I want to know about the sputtering condition of depositing FTO from target 95:5%. I tried with RF sputter in pressure 2.5Pa and 100 sccm Ar at room temperature but it showing no...
21 July 2024 1,680 2 View
I make polycrystalline diamond with tape casting followed by HPHT sintering. When i sintered the samples up till May, the sintering was good. When i sintered the samples in June and July at the...
16 July 2024 3,212 5 View
In deriving a model of an LTI dynamic system, the model of the system does have no RHP zeros, however, when inspecting the step response, it reveals a non-minimum phase system represented by a...
14 July 2024 6,355 2 View
Hello everyone. I am working on my LV concentration porject, I use 500Kda hollowfiber to do it. The HCP and BSA removal rate is nearly 80%, but last time, I failed to run it. The HCP hasn't been...
11 July 2024 5,380 0 View