Whats is the algorithm to define automatically all peaks in 3d data?
you can use the following algorithms.
1. Iterate through the data and identify points that are greater than their neighboring points in all directions (x, y, z).
2. Reduce noise by suppressing points that are not local maxima.
3. Set a minimum intensity threshold to filter out small peaks.
4. Segment the data into regions based on peak connectivity.
5. Group nearby peaks into clusters.
6. Calculate peak properties (e.g., position, intensity, volume).
aAgorithms for peak detection in 3D data include:
1. Machine Learning*: Train a model to learn peak patterns in your data.
2. 3D Gaussian Filter: Smooth the data to reduce noise.
3. 3D Laplacian of Gaussian (LoG): Detect peaks by finding local maxima in the LoG response.
4. 3D Difference of Gaussians (DoG): Detect peaks by finding local maxima in the DoG response.
5. 3D Mexican Hat Wavelet*: Detect peaks by finding local maxima in the wavelet response.
In my study, I intend to infect PBMCs with SARS-CoV-2. After that, I will analyze NK cells by flow cytometry to see if their phenotype changes or if they show degranulation. After the infection, I...
01 August 2024 4,403 4 View
I'm having problems with ion exchange chromatography. After applying my sample (a fluorescent protein), a preferential path inevitably forms. The matrix I use is DEAE-Sephacel. Could someone...
27 July 2024 6,605 0 View
Hello, good morning. I would like to know which plate I can use to infect fresh PBMC with virus and culture for 24 hours. I have tried using 12-well and 24-well plates, but many cells adhere and...
24 July 2024 2,158 2 View
How use this chamber and standarize the data
17 July 2024 1,844 2 View
I am working with microplastics and need to analyze their color, size, shape, and quantity in sand samples. We require a technique that can reliably identify these characteristics. Could you...
13 June 2024 7,216 3 View
The mid-stance or mid-support has been defined as much as a phase or event within the race cycle. However, it did not identify a specific definition or a biomechanical indicator that would allow...
10 June 2024 6,257 2 View
Hi, I'd like to know if someone knows about a company where I can buy an affordable laser-scriber for perovskite films and another thin film for the fabrication of modules. Many thanks,
31 May 2024 2,841 0 View
As keys in input, I used: %Mem=20GB %Nproc=16 %chk=etilantraquinona_professor_func=6-31G_Au_Norte.chk #B3LYP/GEN OPT FREQ=RAMAN Nosymm PSEUDO=READ SCF=TIGHT" **** 0 2 . . . . C O H...
17 May 2024 391 2 View
Regarding the nomenclature of galactans found in agarophytes, which is the correct name for the polysaccharide: "agaran" or "agar"? Why is there so much confusion about the use of this term?
27 April 2024 4,621 3 View
Does anyone knows how to convert an h5ad file into rds file, using an python script?
09 April 2024 1,520 2 View
Do these peaks in the curve indicate primer dimer or non-specific products?
01 August 2024 7,466 0 View
Hi everyone, I'd like to better separate two close peaks coming from a bioconversion sample, I'm currently using a C18 KromaPhase 4,6mm Ø.I. SCHARLAU, particle size (µm): 10, pore size (Å): 100,...
30 July 2024 435 3 View
I do not know much about FTIR! The material Benzethonium Chloride USP was compared to a reference standard in regards to FTIR, as per the USP testing: Identification B. Infrared absorption (FTIR),...
16 July 2024 6,918 7 View
During the release test of Amphotericin B using 1% Tween 80, i observed three peaks even in the standard. The first peak consistently yielded results around 500%, while the other peaks showed...
08 July 2024 1,330 0 View
I synthesized some paramagnetic cobalt and nickel complexes (expected to be Co(II) and Ni(II)) using a bidentate ligand - N of pyridine ring (aromatic) and O of P=O (aliphatic), and I obtained...
03 July 2024 3,410 4 View
I'm trying to fitting Cu Auger peak into various state (Cu0, Cu+, CuI etc..) In Cu0, one of the peak's FWHM is 0.84 but when I try to enter smaller value than 0.89, "input error" is occured. How...
02 July 2024 4,932 3 View
Hello I have prepared metal nanoparticles and did zeta potential. Normally there is a single peak in sample but now there are 3 peaks. I prepared sample for analysis first I prepared 10 mg/mL...
30 June 2024 1,063 4 View
Hello everyone, I'm facing an issue with EDS software that prevents me from obtaining atomic or weight percentages for my scan. However, I do have access to the raw data, which shows intensity vs....
29 June 2024 6,664 14 View
Hi all, I have few XRD files of MoVO oxides. These are newly synthesized compounds. Can anyone suggest me, how can check my XRD files from database? I want to match my XRD peak to the database. Is...
24 June 2024 6,448 3 View
When I examined the GIXRD data obtained recently, I observed that the sample treated with O2 plasma on the Cu surface deposited on Si chips showed increased intensity compared to the sample...
19 June 2024 6,900 5 View