I measured the concentration of Radon 222 and 219 in vegetable samples. I used Cr-39 to measure the concentration in that samples.
I think Cr-39 good device and good way to measure the concentration of Radon isotope.
Dear Dr. Akrawy
You right if we want to measure Rn-222 but, what about Rn-219?
I think RAD 7 is better than CR 39 to measure radon 222 because the error of CR 39 is higher than RAD 7
Dear Fatimh,
Thank you for your answering. Yes you right, but how will separation between them?
Alpha spectrometry is probably the best way. The alpha particles ejected from the two isotopes have different energies. These two isotopes cannot be resolved with CR-39.
Thank you, Dr. Mounir,
Do you mean for active is HPGD, or what you mean?
Thank again
05 June 2017 275 1 View
I'm targeting to deploy a mesh network and manually configure MANET routing protocols. I'm preparing scenarios, architectures, and hard devices needed to do that. Are there some step-by-step...
03 March 2021 1,931 5 View
Hi, I want to start testing pitfall trap to obtain ants samples, but I need to conduct molecular analysis on those insects. So, what kind of fluid can I use? Ethanol expires too early and I need...
03 March 2021 5,978 5 View
I am using a 2707 waters HPLC device. When I try to inject a sample, it says missing plate or rack. I changed the needle and calibrated its position but I still get the same problem. I even get...
02 March 2021 1,408 1 View
I am wanting to calculate the average trend in maximum annual NDVI in Iceland from 2010-2020 using MODIS MYD13Q1 V6. How would I do this? I have currently inserted the NDVI bands from the MODIS...
02 March 2021 752 2 View
Dear All, I have access to some rodent fecal samples that have been stored at -20C instead of -80C. Anyone have experience with the impact of stowage condition on comparative metagenomic analysis...
01 March 2021 2,512 1 View
Hi Community, I'm facing the issue of integration/compiling a new routing protocol in a WSN simulator. The final goal is to successfully add, configure this routing protocol in hardware devices...
01 March 2021 9,332 6 View
When you use RIA, with a control the unknown sample with antibodies, you bare in mind the binding sites of the antibodies. However you still need to measure labelled antigen (radioactive) and not...
28 February 2021 2,133 3 View
I like to do project in laser measurement system. My objective is to eliminate or reduce the cosine error, abbe error in Laser measurement system. I have Rhenishaw XL80 system. Please tell the...
28 February 2021 4,890 3 View
I have a sample of treated water sample & asked to obtain ammonia conc. in sample using a machine with 5-25 ppm detection range. However, upon testing with different dilution factors, all...
27 February 2021 8,483 3 View
If I want to compare characteristics of 2 groups of patients, one group is recruited from a random sample of the general public while another group is from a sample with a fixed gender (male to...
26 February 2021 3,526 3 View