I measured the concentration of Radon 222 and 219 in vegetable samples. I used Cr-39 to measure the concentration in that samples.
I think Cr-39 good device and good way to measure the concentration of Radon isotope.
Dear Dr. Akrawy
You right if we want to measure Rn-222 but, what about Rn-219?
I think RAD 7 is better than CR 39 to measure radon 222 because the error of CR 39 is higher than RAD 7
Dear Fatimh,
Thank you for your answering. Yes you right, but how will separation between them?
Alpha spectrometry is probably the best way. The alpha particles ejected from the two isotopes have different energies. These two isotopes cannot be resolved with CR-39.
Thank you, Dr. Mounir,
Do you mean for active is HPGD, or what you mean?
Thank again
Convert the Activity to Dose Rate
05 June 2017 424 1 View
Air moisture harvesting Air water collection devices
06 August 2024 5,473 2 View
I am planning to collect human fecal samples for metatranscriptomic analysis using MGI. These samples are from indigenous people living in a region with high temperatures. I will have access to a...
06 August 2024 1,367 3 View
Dear all, I am working on analyzing data from a survey on student satisfaction. The survey contains items with a 7-point Likert response format that produce 12 scales related to different areas...
05 August 2024 2,141 4 View
Are there any statistical methods to justify your sampling technique using SPSS or AMOS?
05 August 2024 9,153 4 View
Hello. I am working on ROS production of two systems: system A is cerium oxide and hydrogen peroxide, system B is cerium oxide nanoparticle, hydrogen peroxide and potassium bromide. I did some...
04 August 2024 5,974 3 View
I am conducting a qualitative study that uses interviews to investigate the perceptions of teachers about a particular leadership practice and I am focusing on 3 schools which have a total number...
01 August 2024 8,457 10 View
What types of mask designs for metal deposition, to be used in a PVD system, are best suited for perovskite-based solar cells?
31 July 2024 4,835 3 View
Dear researchers, Why specific capacitance is not proportional to the specific surface area? I have material A with a surface area higher than material B, but material B is showing little bit...
26 July 2024 9,156 2 View
I isolated microbial DNA from marine water samples taken at various sites using the Qiagen Power Water DNA Isolation Kit, including a modified enzymatic lysis step. I encountered a situation where...
24 July 2024 9,688 0 View
I am giving starvation stress to the soil amoeba (Dictyostelium discoideum) cells in my study groups and using NAC as a negative control. I am using DHE for ROS measurement.
20 July 2024 6,354 0 View