I obtained the thin film using spin-coating method by using sparingly soluble solvents like( THF, DMF) having the rpm 1500 for 60 sec.
Generally, the shift of the peaks in XRD can be attributed to:
1- The change of the d-spacing of the investigated system, this may attributed to many reasons including the effect of dopant, strain, surface (for nanomaterials
How the effect of the dopant and strain attributed to change of d spacing in the investigated system?
Please refer to any textbook on XRD, Elements of X-Ray Diffraction by Cullity, B. D is a good one.
Also, you can find details on previous RG answers:
https://www.researchgate.net/post/Any_suggestions_for_why_the_XRD_peak_shifts
https://www.researchgate.net/post/When_XRD_analyzed_what_does_it_mean_when_a_shifted_peak_is_either_left_hand_or_right_hand2
https://www.researchgate.net/post/What_is_the_reason_of_peak_shifting_in_XRD_towards_higher_angle_side_after_the_sample_has_been_irradiated
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
How can I determine a good adhesion strength range for coatings on polymer surfaces, such as DLC on polymer substrates? Is there a specific threshold for adhesion strength (from T-peel tests)...
10 August 2024 942 3 View
We have observed that tube to tube sheet joint leaked in our boiler and needs to overcome same by knowing the root cause.
08 August 2024 3,161 0 View
I did PR spin coating on trench structure. I used AZ P4620 PR and the thickness or PR is around 11um. The substrate is Si. And my trench structure depth is 141um(negative way). Even though I...
08 August 2024 2,298 0 View
Require for Rietveld refinement in XRD.
08 August 2024 3,081 2 View
I need a very narrow glass capillary for my research. How can I make a glass capillary with an inner diameter of around 200 to 500 nanometers?
08 August 2024 8,915 0 View
I need to do some experiment with it in liquid form.
07 August 2024 613 3 View
I have been getting a low plasma and no coating while doing rf sputtering of copper doped ZnS using a power of 140 watts and at pressure of 6.5x10-3 Mb.
07 August 2024 4,526 4 View
During low-temperature testing, new diffraction peaks that appear could be indicative of several phenomena. In one of our tests, we observed notable new peaks around 40° and 45° in a specific...
06 August 2024 726 3 View
I want to refine one XRD peak of my in-situ xrd but the background is never working good which ultimately fails the refinement. How to refine and adjust the background using GSAS-II
05 August 2024 5,291 2 View