Hi all,
For Massive MIMO detectors what is the diversity order of Gauss Seidel and Neumann Series based detectors? The diversity order of Zero Forcing detector is Rx+Tx-1 while Maximum Ratio Combining detector has the diversity order 2Rx.
Thankyou.
i believe this article is advantage
Article An SNR Approximation for Distributed Massive MIMO with Zero Forcing
Simple question, not so simple solution. Am eager to learn so am following.
Hadi Jabbar Alagealy : Really appreciated. Thank you.
Jose Risomar Sousa : Indeed. I will let you know about the solution once i refine my derivations. Thank you.
which regression analysis will be applied if there are 7 nominal dependent variables(YES/NO categories) and 1 ordinal independent variable(3 categories: Low, normal, high)?
23 April 2024 9,971 3 View
While making forest plot Revman I label the plot as Left control and right experiment. I see that the data supports the control as the diamond is on the left. But when I change labels the...
25 February 2024 3,144 2 View
How grain size effects the antibacterial properties?
30 January 2024 6,225 1 View
Techniques Tools required Step by step Procedure
21 January 2024 8,960 0 View
In CSt how do we calculate Power handling capacity of h plane horn antenna
12 December 2023 1,713 0 View
I've tried the liquid exfoliation method but I'm not getting the results. If anyone else has tried through this method can anyone share protocols so that I can check where I'm making mistakes in...
10 September 2023 3,753 0 View
Hi everyone, I have problem while saving the computed points after adding the break lines in 2d unsteady flow. here i have attached the image of the problem I'm facing.
07 September 2023 2,235 0 View
I am conducting CV analysis of a rGO-based electrode using CHI 650E workstation with platinum foil as counter electrode, an Ag/AgCl reference electrode, and 1M H2So4 electrolyte. How can I decide...
07 September 2023 5,403 4 View
I got negative potential window in the range of -0.6 to 0.3 for 3 electrode system ,so can I use negative voltage window for -0.6 to 0.4 for 2 electrode supercapacitor system.
03 August 2023 1,765 0 View
while I am performing EIS in Autolab (NOVA 2.1.6) Metrohm,there are three types of options are available .what is difference between them .
27 July 2023 4,499 0 View
The module of the CAD detector is corona Veo. It has been idle for a long time. And it was not well maintained before idle. I have replaced the gas filters and flushed the system with a 50/50...
01 August 2024 7,805 0 View
I am trying to configure the instrument in Profex but I can't get a chi-squared value below 9.65 for LaB6. This is the configuration of the equipment, which is a Bruker D8 Advance with a Linxeye...
14 July 2024 4,767 1 View
Somewhere on the internet, it's reported the maximum diversity gain limit theoretically can be achieved is 10dB. Some papers said it increases with more antennae and some said it will decrease.
09 June 2024 5,121 2 View
The gases from watter spitting process and I'm trying to measure the H2 by GC. Could anyone tell me what is the best temperature to do that using column porapak q?
29 May 2024 6,068 3 View
Hello We are looking forward to buying the best gold nuggets and other gold form detectors. Additionally, if it detects other metals, that will be an added advantage. We do not want to scan it a...
10 May 2024 1,767 0 View
feasible: all to one (UDP unicast or multicast) stream traffic, images from all mobiles/nodes sent to one mobile/node. TCP modified for node-to-neighbour operation or end-to-end. Can rely on...
05 May 2024 2,535 1 View
I am currently trying to get a Skyscan 1072 micro CT to work again. After the mainboard on the original PC died, we tried to set the machine up on a new computer. We managed to control the source,...
28 April 2024 381 0 View
I am trying to detect organic acids on my waters LC, which is equipped with a W410 refractor index detector. I am using a Aminex HPX-87H Column which is supposed to work to separate organic acids....
26 April 2024 3,036 1 View
Hello, I want to pulse voltage with sourcemeter to measure peorvksite detector, but I found that this model doesn't have sweep button apart from other model. If there is anyone who uses this...
18 April 2024 1,677 0 View
Greetings, despite MIMO and array fall under the umbrella of multi antenna system, what are the features that distinct one from the other. At the same time, what factors makes one to be far...
16 April 2024 9,905 2 View