What could be the highly reflective p-type metal electrode to be used on p-AlGaN surface for UV LED, except Al or Mg-p-electrode? Mixture of two or three metals if any?
Thank you in advance
Hi every one. I am looking for some suitable Laser annealing system in Tokyo area for Mg-doped p-type AlGaN annealing. I am aiming for p-type AlGaN UV LED. Do you have any idea? Thank you in advance
09 October 2017 5,013 2 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
I am using a Sutter electrode holder for my patch clamp experiments, but I'm having trouble keeping positive pressure inside my electrode due to a leak out of the back of the holder. I have added...
02 March 2021 5,829 1 View
I want to do RF sputtering of ITO on glass substrate using magnetron sputtering. what thickness do i need to make it good conductive layer to use it for PSC. Moreover, whats about thickness of...
01 March 2021 395 3 View
I am doing my thesis on the nutrient deprivation on the macroalgae Rhizoclonium sp. I will be analysing the levels over a period of roughly 5 days by HPLC-UV and GC/MS. I will be using seawater as...
28 February 2021 6,477 1 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
Good day to all, I have no experience with light emitting diodes. I am building a glass mini flume to demonstrate the photo degradation of Methylene Blue in water running over self cleaning...
26 February 2021 4,026 5 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
I am trying to characterize an electrochromic system. The system uses ITO electrodes on glass, WO3 as the electrochromic film, and NiO as the ion storage layer. When I deposit NiO and WO3 and...
23 February 2021 9,592 2 View
What are the testing rate for electrodes recommended by ASTM for cochlear implants. I am currently doing the 15mm/min elongatio testing.
22 February 2021 1,515 1 View
One of my colleagues said, "the impedance you can measure with the three electrodes and with the specific sequence varying the frequency" Is it possible to configure the potenciostat without the...
21 February 2021 418 2 View