What are the possible reason behind the presence of unwanted elements which is predicted during EDAX analysis
If I rigthly understand, you find in your sample unexpected elements. The reasons could be different: impurities, contaminant...it depends. Have you got a specific case in mind?
Yes i find unexpected element
And thanks for your information
Dear Subba Raidu ,
you may share your spectra and the unexpected finding(s).
Among the reasons mentioned by Marcella Bini , you may suffer from sum peak(s) and escape peak(s).
Just share the spectrum and we might solve your issue...
Best regards
G.M.
Actually my data is going to be publishing. So, i dont want to reveal my data.
Sorry
And thanks for your response
Ok, Subba Raidu , thanks for feedback;
perhaps you may share these data on a private (non-public) basis via RG messenger ...
Ok sir how to proceed for that
just send me the EDX spectrum as attachment...
(preferably as -pdf , .jpeg or word document)
(go to my RG home page and press the 'message' button)
Alternatively, I will now send you an RG message and you may reply...
(for an alternative way of (private) communication, my E-mail will be attached to that message)...
My research aims at enhancing metacognition. For this purpose, I would like to use MSA for assess metacognition, however, I have not been able to find it.
13 July 2023 6,365 0 View
Question is related with the chilling requirement of different crops
02 May 2023 7,876 0 View
Hi all, I have been trying to isolate protoplast from in-vitro grown young leaves (by shredding into small pieces)of large cardamom (A. subulatum) belonging to Zingiberacea family in enzyme...
30 July 2021 1,603 3 View
My research design is quasi-experimental.I am using critical purposive sample. I want to use quantitative survey questionnaire to collect data. Can I use quantitative survey questionnaire to...
12 January 2021 2,917 5 View
I'm also studying PhD on the topic 'A study on Anchor investment and IPO returns in India'. In my research i'm basically trying to compare price performance of Anchor backed IPOs and non Anchor...
10 June 2020 2,955 0 View
If you had a data set which exhibited both non-normally distributed and non homogeneous,which statistical test would you use compare two sample mean? if i go with parametric test normality and...
04 March 2020 2,771 9 View
Dear Professionals, Kindly do share with me the sample questionnaire of Structural Equation Modelling (SEM) along with any of the reading material for the theory as well. 1). What are the major...
01 January 2020 1,644 2 View
Actually im working on Initial public offering In India.Where SEBI market regulator has introduced a new concept Anchor investor in 2009.So now i have collected data of IPO listed on NSE platform...
21 December 2019 4,066 4 View
One of my research work does not seem to get any relevant literature. So I am wodering how will this research be if not supported by any literature.
27 March 2019 5,734 25 View
Anyone who has used both SPSS and SYSTAT software and can provide insight as to whether latter is as good? Are there any hitches in SYSTAT? Planning to shift to SYSTAT, so seeking information....
17 March 2019 8,235 2 View
CK, OK, NAK MEANING IN SEM EDAX GRAPH
02 October 2023 8,337 6 View
Dear Experts, I would like to understand the analytical value interpretation of my sample which is subjected for elemental characterization study by EDAX SEM analysis. The reported results...
02 June 2023 9,129 2 View
I deposited around 50 nm thick FeGe film on a silicon wafer using a DC magnetron sputtering. The compositional analysis data from FESEM EDAX at the deposition area shows that the oxygen atomic...
17 November 2022 4,036 8 View
EDAX ZAF Quantification (Standardless) Element Normalized SEC Table : Default Elem Wt % Chem K-Ratio Z A C K 52.50 5.92 0.1691 1.0276 0.3133 1.0002
31 October 2022 9,582 2 View
We have done the Energy Dispersive X-ray Analysis (EDAX) of BiOCl, but other than this method which method is the best to determine the elemental composition of BiOCl?
11 September 2022 9,930 1 View
Voltage is 20kV with 95mA. Prob size large (18). Jeol 7000f. Aztec software.
13 July 2022 4,697 7 View
I have rice husk and ash samples and want to evaluate them quantitatively for elemental composition. I would like to compare the results between samples and choose the best sample. So I would like...
11 January 2022 7,619 5 View
i need to get characterization reports for my synthesized manganese oxide nano particles.
21 May 2021 9,996 5 View
I have come through a few literature,were the presence of particular clay mineral has been validated through the Si:Al ratio obtained from EDAX analysis. But, I would like to understand the basic...
08 January 2021 6,299 6 View
Regarding EDAX data analysis Is it possible to change these wt % values in to numerals to do the statistical analysis. If so, how to do? Can anyone please tell? Calcium: Wt% (52.41) and At %...
24 August 2020 6,170 3 View