What are the materials (non-biological and biological ) which are more sensitive to the Polarized Light Microscopy and how can we increase the sensitivity of the material under study. Thanks
Hello dear researchers, has anyone experience in obtaining the monolayer of material MoTe2 successfully by the mechanical exfoliation method ?? I have tried a lot of times, but the best thinner...
08 September 2018 7,611 3 View
Hello dear researchers, Is that true, due to the modulation, we can map the weak signals and alone with modulation, we can get super-resolution??? If we can get the weak signals by using...
08 September 2017 3,241 0 View
Hello dear researchers, Scanning near field microscopy is a standard method for mapping the near field localized amplitude and phase. Is that possible, by inverse calculation( Inversely fit the...
07 August 2017 619 17 View
Hello dear all researchers, as we all know for the single sphere (Monomer) we have Mie solution of the Maxwells equations. By using Mie theory, we can easily calculate the multipolar effects...
07 August 2017 6,382 10 View
I have already used COMSOL, FDTD, and CST software, But they do not offer to map the near and far field distribution at the same simulation area around the particle. Is there any way to simulate...
07 August 2017 4,429 3 View
Hello, dear researchers, I want to ask that I am using the system as shown in figure 2. I performed an experiment and I measured total reflected intensity from the CCD as shown in figure 1(a). I...
09 October 2016 892 7 View
hello dear all, i have performed some NF measurement on nanoparticles whose size range in the 500nm to 1500 nm with wavelength of 532 nm. The system is like polarization microscopy. i have heated...
05 June 2016 7,899 4 View
Hello Dear researchers, especially from China, I want to study the NF and FF scattering from Chiral shape nanoparticle of the size ranges from 700 nm to 1200 nm, From where i can buy in a cheap...
05 June 2016 4,300 4 View
Hello dear researchers, I have Tio2 nanowires, what will be possible effects on scattering spectra if we anneal them at 700C and 800C. Thanks
04 May 2016 1,877 6 View
Hello Guys i want to know that what are the possible ways that we can image the object beyond the diffraction limit using polarization Modulation?
04 May 2016 4,419 5 View
I have virus (viral hemorrhagic septicemia virus) in suspension and the experiment will not involve cells. What level of TCID50 is preferred?
11 August 2024 3,115 1 View
I used eye tracking to examine how participants from two different populations (A and B) react to an image. Participants in population A exhibit larger pupil sizes over time, but they also have...
10 August 2024 3,229 0 View
Fatal error in MPI_Allreduce: Other MPI error, error stack: MPI_Allreduce(1628)......: MPI_Allreduce(sbuf=000002459254A180, rbuf=000002459F86A140, count=4851, MPI_DOUBLE_COMPLEX, MPI_SUM,...
09 August 2024 7,615 1 View
Hello dear colleagues, We have prepared a manuscript on NiTi-based alloys and are seeking a second opinion on our current TEM results. If you are a Ph.D. holder with experience in TEM and have...
07 August 2024 9,563 0 View
What is the prepared reference material that can be used in the ICPE-9820 Shimadzu Japan instrument, which employs inductively coupled plasma optical emission spectrometry (ICP-OES) to measure...
06 August 2024 1,896 1 View
After immunohistochemistry of previously fixed in PFA and EtOH and then frozen 20 μm sections of zebrafish brain, DAPI staining is very weak (right) compared to the same sections stained without...
05 August 2024 9,637 2 View
Citi BLOC Standard Basket Definitions: A standardized unit representing a fixed basket of construction materials, labor, and equipment costs priced in various cities. Purpose: To create a common...
04 August 2024 8,997 1 View
average particle size calculation from TEM
04 August 2024 2,921 1 View
I am working on a SEM model where i have 7 latent variables (6 exogenous and 1 endogenous). In AMOS when I co-vary the exogenous constructs, only 2 paths are coming significant out of 6. But when...
03 August 2024 6,028 4 View
Hi everyone, Recently I have been conducting Dynamic Light scattering experiments in a micellar solution at 5 and gel at 37 degrees of Celsius with latex particles of diameter 190-500 nm. While...
01 August 2024 1,168 4 View