2. If you downloaded it recently then check the java appropriate version is installed on your computer or not ?
3. then install it on your computer.
4. download the components.cif file and paste them in to the data folder of pdbsum.
5. Click on Edit menu and set the few program paths installed at specific location on your compouter (components.cif , temp folder, rasmol or pymol program) .
As Filippo Prischi said, when you are installing Ligplot for first time you have to define path for the temporary file to be stored. So in the 2 line its written c:/tmp. therefore create a new folder in your C drive and name it as tmp. save this and Voila!!!!!
Here I'll try to summarize the system configuration (setting path) on the first time run:
PDB paths - it is ok to leave it as it is (default)
The Het Group Dictionary - easiest way is to just copy this link: ftp://ftp.wwpdb.org/pub/pdb/data/monomers/components.cif however this will limit the use of LigPlot since it will require internet connection
Temporary directory - easiest way is leave it at default and as mentioned Naiju Thomas, just create a folder named tmp at the C: directory.
Rasmol executable and PyMol executable - leave blank or type in NONE if you dont have these. Otherwise, you need to identify the location of their respective executable file within the program files.
I solved this exact problem by first, creating the input .pdb file for ligplot as followed:
1. Open the enzime and the docking result from autodock vina (all conformations of ligand)
2. Save (save molecule) the specific ligand conformation that you chose. Close pymol
3. Open Pymol again and open the protein and also open the specific ligand conformation that you just saved.
4. then click on save molecule and select both the protein and the ligand. Close pymol
5. Finally, open pymol again and open the file saved on point 4. Then click on export molecule and select .pdb. This is the file that will run on ligplot solving the error. Nor Hasmaliana Abdul Manas