Iam not able to see the plot for charge density though i did the calculation part. CHGCAR files are also creaed but uamnot able to analyse. please help
Did you try to use VESTA or XCRYSDEN? It is prety easy!!!
VESTA is one of the common and easy to use methods to visualize charge density.
You can visualize valence charge density and difference charge density using the following steps:
1. In Analysis part choose the option valence charge density or difference charge density.
2. If the charge density of the structure is already calculated, select the structure you want to visualize.
3. You can add surface and tune isovalue for better visualization.
The resin bonded carbon containing refractories are aged before use. How time of aging is determined? And mechanism behind aging.
23 July 2024 3,205 0 View
I was performing estimation of Total Soluble Sugar content in bacterial cultures by Anthrone method. Out of 9 samples, only one sample showed positive reading while others had a negative reading...
22 July 2024 9,576 4 View
I am new to research. The boiling point of triethyl amine (NEt3) is 89 degrees centigrade. I am skeptical that when I will let the hydrogen escape which is getting generated in situ, I will also...
21 July 2024 7,284 4 View
Sometimes I see the shadow like bands and its not true band. I want to know that what's the reason for it. I am using 2% gel for running genotyping samples I have uploaded the gel picture in both...
19 July 2024 148 6 View
What is the future scope of acoustic emission?
17 July 2024 1,510 1 View
I have a small molecule reagent with a boc-protected amino group. Now the reaction needs to be reacted at 37°C for 30 h. Is this protection group stable?
12 July 2024 3,745 2 View
I am trying to measure the plasmon resonance angle of gold film and pure water using the Kretschmann configuration and a 633nm laser. Without flowing water over the gold, I can detect a clear...
10 July 2024 4,719 3 View
I was reading papers on plant secondary metabolites and their applications and many of the papers/books I read, have the point that plant-based medicines which are the result of application of...
08 July 2024 9,935 10 View
Hello! I am facing a problem, I tried using pdb2gmx to generate topology file but it shows error HEA residue not found then I tried copying the forcefield file and edited accordingly but again...
24 June 2024 1,242 0 View
(Transfection with two plasmids has worked for this cell line. pRL-TK(Renilla) is not getting transfected).
16 June 2024 6,687 2 View
"PUBLISHING IN A SCOPUS JOURNAL" Researchers are now at a cross road. The critical need to publish in a Scopus or ISI, etc journal is ever vital. Journal Publication fees must be submitted....
10 August 2024 8,621 1 View
Hello everyone, I am currently developing a thesis proposal and would appreciate your input on its viability and how to effectively carry it out. My proposed topic is: "Does the perceived threat...
10 August 2024 8,992 0 View
Who will bear moral responsibility for the deaths of thousands of people in the event of an earthquake? Weeks and months remain before the onset of strong earthquakes that bring death to...
08 August 2024 6,134 12 View
Hi, Recently I was running VASP to calculate the spontaneous polarization of my alloy structure. I followed the instructions in this PDF wrote by Dr. Nabin (Nabaraj) Pokhrel, below is my INCAR...
07 August 2024 486 5 View
The paper in question is "Interpolation of Nitrogen Fertilizer Use in Canada from Fertilizer Use Surveys". This paper was very recently published by Agronomy (MDPI). Agronomy has, in the last day...
07 August 2024 9,934 3 View
Program: g_mmpbsa, version 2024.1 Source file: extrn_apbs.cxx (line 152) Fatal error: Failed to execute command: $APBS pybYcUWA.in --output-file=pybYcUW.out
07 August 2024 6,066 0 View
The first pdf file I uploaded had an error. So I uploaded an updated, corrected pdf of that paper with a different pdf name. I dpon't want the old copy to be download or read.
07 August 2024 9,508 1 View
Dear QE-users, In the method where full MS positive mode and PRM mode are used, we always get an incorrect auxiliary gas reading (41 instead of 25). This only happens in this method; other...
06 August 2024 4,953 0 View
There are a huge number of methods for studying objects in space, according to the senses (and not only). Mechanical, thermal, optical, acoustic, electrical, magnetic, based on particle beams,...
06 August 2024 7,102 0 View
In the case of a wound l recurrence after radical breast cancer and sentinel lymph node biopsy. Are the sentinel lymph node procedure recommended? If no axillary lymph node dissection was not...
05 August 2024 8,056 1 View