I am trying to run Second degree cfa in AMOS. As far as I know I must fix second degree factor's variance to 1. But when I right click to I can not see fixing option.I mean there is no box to fix 1.
You can do it as follows:
For the second order measurement: delete (0) in Mean and put (Variance=1).
No fixed values (1) of those associated with the second order variable
I agree with Dr. Mahfuz
hello, I want to run a MIMIC model in AMOS, is there a ideal number of cause indicators? Thanks on advance,
08 September 2019 8,844 10 View
Hello, My friend created a hypothesis "Is x (variable) is significant?". I found this hypothesis weird:) Anyway, he insists on testing this. I calculated the mean of the scale (x) on SPSS. Is...
07 August 2019 7,012 6 View
Hello, I am trying to run CFA for likert construct? But linearity assumpition is violated. I do not have the oppurtunity to lessen the number of items but there are a lot of items which do not...
31 December 2018 1,046 0 View
How can we interpret negative factor loading? In explanatory factor analysis, how should us interpret negative factor loading? Should we consider absolute value?
31 December 2018 6,805 1 View
In explanatory factor analysis, I have an item loaded positive in one factor and loaded negative in an other factor, there is a difference less than 0,1 between the two in absoulte terms? Should I...
11 December 2018 6,916 1 View
In structural equation modeling, ECVI is an index that can be achieved in an other sample. But formulation of ECVI does not explain how this works?
11 December 2018 7,236 3 View
In reflective models, should regression coefficients between latent and two indicators have same sign?
10 November 2018 3,138 4 View
Is it necessary to test the significance of marker indicator in SEM? I have a SEM model in which latents have two indicators. I estimated hybrid model using one step approach. When I release...
10 November 2018 1,207 3 View
10 November 2018 4,882 0 View
In my structural equation model, I have a an observed egzogenous variable, according to modification indices, can i link it to an indicator of endogenous latent? Thanks in advance
10 November 2018 6,878 7 View
I have face this problem anyone help me how to solve this issue ?which is below Fatal error: There are inconsistent shifts over periodic boundaries in a molecule type consisting of 78 atoms. The...
07 August 2024 2,598 1 View
Dear QE-users, In the method where full MS positive mode and PRM mode are used, we always get an incorrect auxiliary gas reading (41 instead of 25). This only happens in this method; other...
06 August 2024 4,953 0 View
Are there any statistical methods to justify your sampling technique using SPSS or AMOS?
05 August 2024 9,153 4 View
Hello guys! Do you have experience running a Oaxaca-Blinder decomposition on R applying person weights. How do you suggest doing it? I have a variable PERWT which gives more information on how...
04 August 2024 6,033 0 View
I am working on a SEM model where i have 7 latent variables (6 exogenous and 1 endogenous). In AMOS when I co-vary the exogenous constructs, only 2 paths are coming significant out of 6. But when...
03 August 2024 6,028 4 View
Hello Everyone I have a question about structure for connectivity analysis on sources. My goal: preprocess and cut data into trials create headmodels, using template MRI file perform source...
30 July 2024 2,744 1 View
When I run autogrid4 it says: autogrid4: ERROR: Unknown receptor type: "Cr" -- Add parameters for it to the parameter library first! Look forward to your reply.Thank you so much!
29 July 2024 488 0 View
I am trying to run a restart analysis, which imports deformed configurations of parts from a generated ODB file. It runs fine in Windows OS but when I try to run it in Linux OS, it is giving some...
29 July 2024 9,572 3 View
Our department has recently acquired an HPC (High-Performance Computing) system, and I'm thrilled to take my molecular dynamics calculations to the next level using Desmond. I used to run my...
28 July 2024 6,553 1 View
I am preparing to run a lot of samples on a 384 well plate and I wanted to test if any well in my PCR machine is dead so as not to lose any data. I would really appreciate help with how I can do...
24 July 2024 8,172 1 View