This DC Microgrid comprises of wind turbine, PV, FC and two batteries with supercapacitors as DC machines. There are two breakers in the simulation.
I have tried changing solvers or run simulation in Discrete mode. They did not work.
Work on better computer. Also, try to reduce your imbeded codes and blocks.
Try to bring the size of battery down (scaling) and visualise the effects quickly. Then you do not have to wait long. Additionally try to use average models of power converters that will definitely help.
Another way to reduce the simulation time include :
- reduce the sampling time (for example from 10(-6) to 10(-5))
- use another type of solver (with the required parametrization )
It is possible to reduce simulation time by either of the following:
- reducing the tolerance of simulation,
- using solvers that converge faster and
- introducing a scaling factor for the parameters.
Write your own simulation program.
My suggestions are:
Use average models for converters (easy if you are not interested to high frequency harmonics).
Convert continuous state models to discrete state to run at fixed time step (this requires a deep understanding of each module).
Decouple possible algebraic loops.
Simplify the models of cables and TL's.
With both provision should allow increasing the time step up to 10-50 useconds.
Eventually, is a phasor approach completely out of your scope?
Which is suitable for use with Python? MySQL or SQL Server? What is your suggestion?
01 March 2021 3,422 3 View
Hi everyone How to model Supercritical water gasification (SCWG) process in Homer software?
25 February 2021 4,075 1 View
Hi every one Is it possible to define biogas as a fuel in the reformer process(scwg) in Homer software? Biogas fuel is not available in the options thanks
23 February 2021 6,518 3 View
About crack modeling in ABAQUS: Mode I (pure-tensile cracking) and Mode II (pure-shear cracking), these assumptions may be accruing in theoretical approach (ABAQUS) not practical in Lab....
19 February 2021 6,156 1 View
hi everyone I am simulating a unit cell structure in HFSS using Flouquet port having two modes for absorption I have used this formula:- absorption=...
17 February 2021 9,178 2 View
Hello. An article on the Iranian state's civil liability in the COVID-19 issue has been written in collaboration with a friend and a comparative look at law and biology. The article is ready to be...
15 February 2021 2,906 2 View
Hi everyone. I am looking for a high temperature MPCM. More specifically, I need the thermo physical properties of a microencapsulated phase change material with the melting temperature between...
14 February 2021 3,606 2 View
In my research, I have used metaphorical elicitation tasks to investigate learners' conceptualization of speaking fluency. In the analysis phase, I used thematic analysis to make themes out of...
10 February 2021 4,719 11 View
Hello all, I am trying to model CO2 being dissolved in a bubble column filled with water. For mass transfer definitions, I need to define two phases: for instance, liquid and gas, where the liquid...
08 February 2021 2,722 3 View
The hourly load curves of the selected household in each season are shown in Fig. 28. Figure 28 shows the demand for electricity in four months on an hourly basis. Can you explain this diagram to...
08 February 2021 657 16 View
When I tried to energy minimization my system, I got fatal error as below. Fatal error: Atomtype opls_116 not found Although I've already added this line: ; include water #include "oplsaa.ff/spc.itp" to [molecultype] directive in my topology.
16 June 2021 0 0 View
I have tried to download the 64-bit version of MGLtools however, as many times as I have downloaded and uninstall the programs, an error arises that the app needs to be updated. Thank you.
03 March 2021 5,997 2 View
Hi everyone, I am conducting research for my Master's thesis. I am using PROCESS by Johnson-Neyman to analyze my Moderator model. I test the relationship between Public Service Motivation and...
03 March 2021 2,350 2 View
Hello, I'm fairly new to ARENA and I have the following problem: I have two queues in which, in each queue, a different order type arrives (both having an arrival rate of exponential 10). Order...
02 March 2021 2,431 3 View
I just wanted to check if I need to run a linear regression separately if I am using PROCESS MACRO to run mediation analysis. Thank you.
02 March 2021 4,359 3 View
Hello, I have a mechanism where air rises due to convective flows. In this simulation, nothing is driving the air except this. I understand that the Boussinesq approximation only works for small...
02 March 2021 4,910 3 View
Dear Colleagues, After running Western blot on PVDF membrane and detection using ECL, I would like to stain my PVDF with colloidal gold to be able to allign the ECL image with total proteins on...
02 March 2021 7,829 3 View