Dear Anchal Kishore Singh ,
remeasure, please, the same I-V curve setting a competent manual i-mode, e.g. not using the auto-range i-mode.
respected prof. Ioannis Samaras thank you for suggestion. sir i am getting same i-v curve in both (manual and auto range mode).
thank you, for remeasuring I-V.
Say, please, what is your sample (material/device).
Also, send (or message), if possible, a draft photo of your sample, including the (2?, or more) electrical contacts.
I have face this problem anyone help me how to solve this issue ?which is below Fatal error: There are inconsistent shifts over periodic boundaries in a molecule type consisting of 78 atoms. The...
07 August 2024 2,598 1 View
Hi all, I was just wondering if anyone has experience with multiplexing a mouse monoclonal primary and a rat primary. I'm trying to multiplex by incubating them in the same well but was told by a...
06 August 2024 9,707 1 View
I am working on Abaqus/Explicit(Quasistatic ) for the deformation of the auxetic structure model. Please explain how the plastic input value should be considered from the true stress-strain curve...
05 August 2024 452 3 View
How to enhanced h-index in Research Gate?
04 August 2024 3,366 4 View
I want to do wavelet transform of some compounds for their comparative study? Kindly help me in this regard and provide with proper procedure.
31 July 2024 4,169 0 View
I am using CuBr/THPTA for a click reaction in total cell lysates. I am facing issues with my protein sample in non-reducing SDS-PAGE where it's not migrating properly and most of it remains at the...
29 July 2024 949 4 View
How to use energy flexibility in inventory modeling?
29 July 2024 2,192 5 View
Please send me updates regarding the above-mentioned areas in the question mark?
28 July 2024 5,196 3 View
The resin bonded carbon containing refractories are aged before use. How time of aging is determined? And mechanism behind aging.
23 July 2024 3,205 0 View
I'm facing issues with the tumor dissociation protocol for GBM. I use collagenase/dispase with DNase to dissociate my tumor sample. However, even after incubating it for 60mins, I do not get a...
22 July 2024 412 3 View
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,800 2 View
For example, I perform passivation process before electropolymerization of Py for adhesion to titanium surface. Is a similar or different procedure required for ITO? If necessary, I would be glad...
06 August 2024 3,175 0 View
Hi! So i attempted to understand a novel protein behavior towards heat application by analyzing its secondary structure change. I subjected the protein to a thermal denaturation analysis using...
06 August 2024 1,988 3 View
How can I measure the thickness of thin film by Uv-Vis?
06 August 2024 7,809 3 View
Why is TLC not a form of partition chromatography and paper chromatography not a form of absorption chromatography?
03 August 2024 7,034 3 View
I need something like Camag's VisionCat software for photodocumentation of TLCs. Could you recommend something?
31 July 2024 8,415 1 View
My final research is about making chitosan/pva hydrogel for wound healing using gelatin as crosslinker. Last month, i made the thin film hydrogel and it turn well. It was okay. Last week, i make...
28 July 2024 2,794 6 View
I have images of film formed on the bottom of a 50mL beaker, and I have been trying to figure out the surface area. I could easily use features on imageJ to do that, but I want to know which area...
23 July 2024 4,461 1 View
I know that films and other low-thickness laminated products are produced using biaxial orientation, but is there something similar for sheets with a thickness of around 6 mm? Or are they...
21 July 2024 1,559 1 View
I work with planar interdigitated electrodes (IDEs). The finger width and the spacing between the fingers are 5 micron. The surface of the IDEs is coated by a non-conductive polymer layer...
16 July 2024 5,031 1 View