Is humidity introduce when Ar/N2 is used as carrier gas in gas sensor?
02 March 2017 4,466 0 View
Which type of gun/air brush required for this?
09 October 2016 4,877 5 View
Generally, CNTs has poor adhesion on Si wafer, when deposit their thin filmby spin coater. So, I need a solvent that help in good adhesion of CNTs by spin coater...
09 October 2016 6,297 7 View
In my case it comes 5e19cm-2... its very large as compared to reported values....
08 September 2016 4,531 0 View
Any appropriate technique specially for MWCNTs?
07 August 2016 2,499 2 View
with concentration of CNTs in polymer?
07 August 2016 9,405 3 View
05 June 2016 2,330 2 View
generally, MWCNTs behave as semiconductor at room temperature.. in my case at room temperature, its i-v is perfect ohmic, but when we record i-v with temperatures.. i found that its resistance is...
04 May 2016 4,421 9 View
04 May 2016 9,886 0 View
If yes, what about calibration?
03 April 2016 228 2 View
Dear Dr. Cai, my name is Simone Prospero and I work in the team of Phytopathology at the Swiss Federal Institute for Forest Snow and Landscape Research (WSL;...
01 March 2021 1,133 1 View
I am doing my thesis on the nutrient deprivation on the macroalgae Rhizoclonium sp. I will be analysing the levels over a period of roughly 5 days by HPLC-UV and GC/MS. I will be using seawater as...
28 February 2021 6,477 1 View
The following code (see 1st 2 images attached) is used to produce PID controller values that are designed to control the system (G). The code finds the PID controller values (noted as k) by using...
28 February 2021 6,560 14 View
I have a tank which contains natural gas at 250 Bar and 293 Kelvin. I want to cool the gas in a dry-ice cooling bath to about 195 Kelvin. The gas will flow in a copper-tube through the bath with a...
27 February 2021 8,128 1 View
Hi Guys. I'm a mechanical engineer and have a bit trouble, would be very glad if you could help me with my questions. I have a pressurized tank which contains Natural Gas at 200 Bar and 293...
26 February 2021 6,253 3 View
I am trying to obtain the response and recovery times for my gas sensor device. It appears the the response/recovery times are primarily dependant on the flow rate of the gas I inject into the...
26 February 2021 1,511 3 View
Good day to all, I have no experience with light emitting diodes. I am building a glass mini flume to demonstrate the photo degradation of Methylene Blue in water running over self cleaning...
26 February 2021 4,026 5 View
Hi all The question is related to TGA(Thermogravimetric analysis). Thermal degradation easily understood but why do samples weight decrease? altough just binding is broked, the weight of...
26 February 2021 1,100 5 View
Dear All, We are using Autodesk cfd to calculate the air flow in a single sided naturally ventilated room, where air flow depends only on buoyancy due to temperature difference between inside and...
25 February 2021 9,602 4 View
Has anyone ever tried to deliver CO2 with a CGA 300 regulator? I know that a CGA 320 regulator is standard for CO2. The issue is that I currently do not have any free CGA 320 regulators. I also...
25 February 2021 3,292 3 View