How to compute the main stream channel slope with ArcGIS HEC-GeoHMS extension to use this equation to estimate the sediment delivery ratios?
Williams and Berndt (1972) expressed: SDR = 0.627 ∗ SLP0.403
Hi,
I think the basin delineation processes in HEC-GeoHMS also consists of channel slope computation. The main input is DEM, basin and river shapefile, as I remembered I did last time, but you also can find available tutorials on Youtube.
hope this can help,
Hi Nai,
Thank you so much for helping me. This is extremely helpful.
Best wishes,
Ahmadi
Electrospining method is important for production of nanofiber .If doped with nanoparticles ,can be used for remove of contaminant such as VOC , but don't have mechanical strengh . For finding a...
24 January 2021 7,290 3 View
the electrode structure has secondary pore networks , so I need to use different governing equations for the electrodes. I tried to use PDEs , but I have not get any results. Does anybody have any...
02 January 2021 3,225 1 View
I want to optimize the interaction between the the O2 molecule and a metal nanocluster, but I need to know which multiplicities I should choose?
25 November 2020 716 2 View
Hello every one I was wondering if someone could help me solve the problem that I have with my Mass Spectrometer. Actually I have already calibrated my MS device for a mixture of 60% Ar and 40 %...
19 November 2020 2,984 3 View
Dear all, I developed a hybrid Phase Field-Finite Element Model (PF-FEM) for fracture of electrode particles of Li-ion batteries. [Isotropic & Hybrid] Phase Field-Finite Element Model (PF-FE......
31 October 2020 8,810 1 View
Hi Everyone. I have this dimensionless governing equations that I want to solve in Ansys Fluent. But then, in Ansys Fluent, the geometry only dimensional. So my question is, does dimensionless...
17 September 2020 9,096 3 View
I am going to react a free fatty acid with 1,2-epoxydecane.
11 August 2020 8,227 2 View
Hello, I need to grow E. coli in 384 microplates directly from colonies. They contain an Amp resistance plasmid. We cannot shake the plate. I tested LB, but they grow poorly. Any suggestion to...
11 August 2020 5,386 3 View
I want to optimize a crystal structure that contains a mercury atom with six-coordinated (according to the cif file) but in one monomer of this structure only 3 atoms connected to Hg, I have...
07 July 2020 9,523 3 View
Covid-19 in Pharmaceutical and Biomedical Research The novel coronavirus SARS-CoV-2 (COVID-19) is a global crisis leading to huge number of economic losses, morbidity, and mortality. This emerging...
22 June 2020 8,015 8 View
I am going to have 3 different probes in my qPCR work that I am going to do. But I realized that the machine we have in the lab is a Rotor-Gene Q 2plex HRM Platform, saying it has green, yellow,...
01 March 2021 8,544 1 View
Hello I'm currently working on a topic related to studying the anaerobic biodegradation of TPH in marine sediments. In this work, sediment should be mixed with fuel oil to a concentration of 20 g...
24 February 2021 9,839 3 View
Need Help Does anyone Know how to make a Fractional impervious surface (FIS) map from NDVI map, in ArcGIS environment? Thanks in advance
24 February 2021 8,455 2 View
It is a general practice to introduce Ground Plane in FDSOI devices under the BoX. The Ground Planes are introduced by Ion Implantation through Top Si layer and Buried Oxide. I wanted to know that...
24 February 2021 5,974 4 View
Hi there, I've been using the EVOS Auto II microscope for some time now and usually I will save the transmitted light/bright field image and the images from fluorescent channels as separate...
15 February 2021 546 3 View
CSISO= f(frequency) : plot(f, CSISO) ? CMIMO= f(frequency) : plot (f, CMIMO) ?
13 February 2021 5,225 4 View
07 February 2021 3,663 2 View
Dear all, I am trying to optimize a bimetallic complex using # opt=tight b3lyp/lanl2dz scf=qc geom=connectivity. The program is running for around 5 days but the size of the .chk remains same...
05 February 2021 8,721 3 View
Impinger bottles are used at some applications, where the gas is cooled and the condensate is dissolved in a solvent contained in the impingers. I have always seen impingers made of glass. Why not...
03 February 2021 6,959 2 View
I planned an experimental setup using 10-plex TMT with 9 conditions and 1 bridge channel to compare 5 replicates. But since I experienced some run-to-run variation, I was wondering if a better...
31 January 2021 3,405 3 View