I have ftir spectrum response, how I interpret it?
FT-IR is very simple and rapid technique to perform this
analysis. It does not require complex sample preparation.
Spectrum TwoTM gives us the flexibility to run the samples in
liquid phase with 0.1mm path length cells. This application is
useful in oil or petroleum segment wherein we need to check
the quality of oil on the basis of carbon type.
Note: If sample has a large aromatic content (approximately 20
%) the paraffinic peak may become masked by adjacent peaks,
making accurate measurement difficult.
The calculation can be performed either manually or
using software calculations. Then tangents
are drawn across the transmission maxima on either side of the
peak being measured, and a vertical line is
drawn through the peak minimum. The intersection of these lines
gives the value of intensity Io and the intersection of the vertical
with the peak minimum gives value of I. The values are to be read
of Io and I for CA (1600 cm-1
) and CP (720 cm-1
). CN is calculated
from the difference
I have an absorbance graph. How can I convert it to transmittance?
31 December 2015 8,676 1 View
Hiiiii everyone! I have an enquiry on statistical analysis. I was looking for many forum and it's still cannot solve my problem. I want to compare means of two groups of data but only with two...
03 March 2021 8,796 3 View
I am on the lookout for the Enhanced Yellow Fluorescent Protein (Aequorea victoria) DNA sequence. Does anyone know where I can find it? Thank you in advance
03 March 2021 3,568 1 View
Hi, I want to start testing pitfall trap to obtain ants samples, but I need to conduct molecular analysis on those insects. So, what kind of fluid can I use? Ethanol expires too early and I need...
03 March 2021 5,978 5 View
What's the best way to measure growth rates in House sparrow chicks from day 2 to day 10? Since, the growth curve from day 2 to 10 won't be like the "Logistic curve" it might not follow logistic...
03 March 2021 1,401 3 View
I have conducted and published a systematic review and meta-analysis research with the topic related to public health and health pomotion (protocol was registed in PROSPERO). Now we want to...
03 March 2021 8,920 3 View
dear community, my model is based feature extraction from non stationary signals using discrete Wavelet Transform and then using statistical features then machine learning classifiers in order to...
03 March 2021 6,994 5 View
I'm dealing with a mediation model and am using the PROCESS module in SPSS. Due to SPSS and PROCESS being limited in the imputation methods - being unable to handle multiple imputation - the other...
02 March 2021 4,362 1 View
I just wanted to check if I need to run a linear regression separately if I am using PROCESS MACRO to run mediation analysis. Thank you.
02 March 2021 4,359 3 View
If the detection range is in ng/ml but the reference range is in ug/ml for a molecule or protein in serum or plasma .how to dilute and what is the initial volume to be taken for quantitative analysis
02 March 2021 7,670 3 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View