thanks Dr. Aslam Baig. i think from this formula i can estimate electron temperature in plasma. i calculate this formula and i obtain Tg=10000K. it is too much for my setup. i guess the gas temperature is about 300-1000k. so i think the best way is Boltzmann plot. may you send me some reference of this method?
Using the Boltzman equation or Spacair are good for plasma containing molecular component. In this case, rotational structure of molecular bands is recorded.
For atomic plasma, spectral line profile may be used. See, e.g., the paper by Pipa et al. Applied Physics Letters, 2015, v.106, 244104
thanks Dr. Ionikh. but i could not reach the Specair application. i have an question, Boltzmann plot use Doppler velocity? and on the other hand can i measure gas temperature?...i want it to calculate H/H2 and i need Tg.
@Shahab: You have to purchase the license for Specair; it used to be free but not any more. Alternatively, you can use the open source python program, massiveOES written by Dr Jan Vorac et al, MUNI, CZ.
Thanks Dr. Pipa. I exactly follow these artile. But spectrometer resolution is about 0.1nm. I think we have not enough resolution to determine this fraction. By the way formula that introduce in these article would be usefull if you know the gas temperature. So i should determine it.
If there is some obstacle for you, let us know. We may find a bit of time to improve the programme, depending on the complexity of the change required.
Btw., we do not have a database for H2, but if you are willing to build it, we can provide support.
0.1 nm resolution can be sufficient, unfortunately different people define the resolution in different way. However Doppler broadening is inaccessible and if it is no impurities of the N2 (or other molecules) then the Fulher band would be the only information source for the gas temperature. See my dissertation attached, page 93-94, an examples of the measured spectra. It should be possible to resolve Q1 line (3c22a2Q1) but Q3 line can be overlaped with 3c12a1Q9, but Q5 line should be again Ok. I think the estimations of the Tg should be possible. Do not forget a second order filter during spectra acquisition. See pages 55-58 for details.
i found that for determine gas temperature at first we should have spectrometer with high resolution. from the papers and books that you send i consider two ways to measure gas temperature.
1. use Fulcher band and relative intensity as Dr.Pipa send in page 55.
2. use Doppler Broadening FWHM as discuss in paper that Dr.Ionikh send.
Actually I've meant the collisional line profile rather than the Doppler one. In the latter case the profile may be much wider and spectrometer of moderate resolution can be used as is described in that paper. But for your case of H2 plasma this approach is not applicable. Doppler width is ok, but spectometer with very high resolution or even Fabry-Perot interferometer are required. So I believe the Fulcher is the best chice.
That is pretty difficult. AOptical methods aren't great for obvious reasons (like IR thermometers), and of course a metallic thermocouple is not an option.
I'd recommend this. If it's a jet, use some high-boiling liquid (no more than 100 uL) exposed to it for about 1 min. Since the liquid won't evaporate, it will then just be heated up by the gas. And using a thermocouple in the liquid /immediately/ after the exposure is what you need.