How exergy analysis of simple (non-cryogenic) distillation column is different from exergy analysis of cryogenic distillation column?
If possible, can anyone of the experts provide me equations?
send me your process flow diagram with pressure and temperature
Anil Kumar Sakhiya , do you have Aspen Plus v10 installed? I am talking about it`s example named "IGCC", in which under hierarchy "ASU", the cryogenic air separation/distillation section is there.
No I dont have
1, The second law of thermodynamics is incorrect. See figure below for details.
2,The system is isothermal and exchanges heat with a large heat source to keep the temperature constant. Only volume changes are discussed.
3,The problem here is that the actual system is balanced and the second law of thermodynamics judges it to be unbalanced.
What does it mean by cycling in distillation columns?
03 April 2019 1,720 7 View
Guidance requested in writing an optimization algorithm in Aspen Plus..
01 February 2019 4,482 1 View
How to determine the exergy efficiency of heat integrated distillation columns, during cryogenic air separation. Would appreciate if anyone provide formula for both column`s.
01 February 2019 7,242 5 View
I am using "Aspen Plus Optimizer Tool" to optimize the distillation column design with respect to reflux ratio and number of theoratical stages. However, I am unable to do sensitivity analysis,...
31 December 2018 696 17 View
How we can calculate a combined efficiency of a process? e.g. if two compressors are installed, then how can we calculate their combined efficiency? If compressors, distillation column, turbine...
31 December 2018 5,263 4 View
Hello. I am using heat integrated distillation column. However, one of the column`s exergy efficiency is greater than 100%? I have seen a lot of literature but still unable to figure...
11 December 2018 9,999 3 View
Difference b/w Two Softwares results? which one to use? or Report both in the calculation.
31 December 2016 9,895 12 View
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,801 2 View
I would like to learn more about SPSS and Its application especially in regards to data analysis. Please suggest me how I can learn more about it. Thank you so much.
11 August 2024 9,101 4 View
I have reverse sequences (AB1 format), can I base on reverse DNA sequences to perform nucleotide alignment, convert nucleotides to amino acids and deposit the sequence in GenBank database?
11 August 2024 5,138 1 View
Can anyone explain this method? Especially the last statement where it says only at 1.5 to 2.5mins was the MS/MS connected to the UPLC. How is that possible, is it a feature in this specific...
11 August 2024 8,141 3 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
Willett, Shenoy et al. (2021) have developed a brain computer interface (BCI) that used neural signal collected from the hand area of the motor cortex (area M1) of a paralyzed patient. The...
10 August 2024 7,180 0 View
I'm currently exploring the application of Python in textile engineering, specifically in areas like data analysis, process automation, and the development of smart textiles. I'm interested in...
10 August 2024 7,429 2 View
How can I use the cif data obtained from rietveld refinement extracted via gsas2, for microstructural analysis using ETEX software?
09 August 2024 7,718 0 View
I've been performing RNA extraction on cotton petiole tissue for a few months now using the method described in the following paper, a derivative of the typical hot borate method...
08 August 2024 9,882 2 View
Let's say we have a standard, regular hexagonal honeycomb with a 3-arm primitive unit cell (something like the figure attached; the figure is only representative and not drawn to scale). The...
07 August 2024 1,937 1 View