I am optimizing my molecule with LC-B3LYP method and 6311G(d,p) basis set, but the link dies giving me an error;
''Error termination via Lnk1e in C:\G09W\l301.exe''
I am attaching my output file also. what could be the reason?
The hint message at the output bottom "LC correction to exchange needs equal scale factors." needed to be paid attention. Long-range corrected functionals seem should be written as "CAM-B3LYP" in the B3LYP hybrid function method. Reference as below:
http://wild.life.nctu.edu.tw/~jsyu/compchem/g09/g09ur/k_dft.htm
Holp it can help you.
Instead of checking only the mRNA level, I want to check the active protein level of MMP-1 in Liver tissue from mice. How can I do that?
03 March 2021 1,763 2 View
I want to analyses the proportion of swimming sperm of three species of fish in two salinities. To analyse the proportion of swimming sperm in a Generalized Linear Model, I would use a Binary...
03 March 2021 2,297 3 View
03 March 2021 8,272 1 View
Hi. Please tell me what guidelines should i need to follow for questionaries' type research work in India. It is not hospital based work, we are conduction basic institutional based qualitative...
03 March 2021 2,037 3 View
Hi, I implemented a code to gabor filter cifar10 data but the images after being filtered and stacked are not clear like the original images. I think the problem is in the way I am using the...
03 March 2021 6,317 1 View
i am try to classify the x-ray images. During classification , can i block unwanted images (except x-ray image).
03 March 2021 7,100 1 View
03 March 2021 5,360 2 View
The term miscibility refers to the single-phase state in thermodynamics. I do not mean the compatibility of different components. To determine the miscibility I know several techniques such as...
03 March 2021 4,107 4 View
If the detection range is in ng/ml but the reference range is in ug/ml for a molecule or protein in serum or plasma .how to dilute and what is the initial volume to be taken for quantitative analysis
02 March 2021 7,670 3 View
02 March 2021 5,204 3 View
Hi, I am using GROMACS 5.1.4 to simulate water in contact with a surface. I am only interested to calculate some properties of water near the surface. Let's say at a distance of x nm from the...
03 March 2021 9,989 2 View
I have prepared a manuscript in IEEE Latex template, but for some purpose, I need to prepare a word file as well (detailed format is not required). Compared to two column .tex file, one column...
02 March 2021 1,830 3 View
Question to you and THEM, the New Journal, "Integrative Psychological and Behavioral Science" -- do you not know, and have you not seen, this done before? There appears to be a core problem for...
02 March 2021 3,024 2 View
Hello, I am working on a soil project and I found a primary research article that tests how the modification of agricultural soil can cause global warming, using a thermal collector, however I...
02 March 2021 7,161 3 View
I made a vertical section plot with WOA .nc file on ODV, and now I want to plot my stations (csv. file) in it. Does anyone know how to import my points to the section? They are two different...
01 March 2021 3,610 1 View
Hello every body Does any one has any idea to help me choose a reasonable basis set for intermediate metal ions (i.e Fe2+, Mn2+, Cu2+ and exc.) interactions with guanine or other DNA organic...
01 March 2021 6,187 2 View
01 March 2021 1,290 2 View
Im doing PBMC isolation -> CD14+ enrichment using magnetic beads -> stimulation setup. My negative control is just cells in cRPMI but they seem to get activated over and over again.
28 February 2021 7,883 3 View
Is there any reason for decrease in fluorescence emission intensity of HSA,BSA when increase the concentration ?
28 February 2021 3,653 4 View
I've used the "export data" option in Vesta software to convert my unit cell into a cif file however when I use that cif in atomsk it shows error such as "can't read the position of atom 0". If I...
28 February 2021 4,966 3 View