could someone explain what will be the effect of cooling rate on shperoidisation annealing ?
Dear friends, I'm working on 26MnB5 Hot rolled steel,micro analysis reveals the presence of C/Mn segregation along with the ferrite / pearlite bands. I analysed the segregation area ,...
04 May 2018 6,333 0 View
05 June 2017 1,219 0 View
03 April 2017 3,833 3 View
*The max allowable hardness - 22 HRC
05 June 2016 7,534 0 View
03 April 2015 1,558 2 View
The figure shows DSC cooling (blue) and 2nd heating (green) curves (step: 10 K/min) for a commercial sample supplied as Atactic Polypropylene (APP). The heating curve illustrates two major...
03 March 2021 5,857 3 View
Hi, I am running a size exclusion chromatography experiment with a buffer containing Potassium Acetate as a salt. I analyse these fractions through SDS-PAGE. After boiling my SEC fractions in...
01 March 2021 2,622 3 View
I have a tank which contains natural gas at 250 Bar and 293 Kelvin. I want to cool the gas in a dry-ice cooling bath to about 195 Kelvin. The gas will flow in a copper-tube through the bath with a...
27 February 2021 8,128 1 View
Hi Guys. I'm a mechanical engineer and have a bit trouble, would be very glad if you could help me with my questions. I have a pressurized tank which contains Natural Gas at 200 Bar and 293...
26 February 2021 6,253 3 View
I have radial blade centrifugal fan design which will be mounted on exhaust side of electric traction motor. The fan will be mounted on same motor shaft inside the housing. How can I verify that...
23 February 2021 2,390 3 View
Hello, The UN Office of Outer Space Affairs has a program called access to space for all that enables institutions to have hands on expertise related to access to space. There are three elements...
22 February 2021 7,980 3 View
How do the thermal conductivity, specific heat capacity, plastic strain, critical compressive displacement, and thermal expansion of both hot-rolled steel and concrete change after cooling based...
15 February 2021 1,385 5 View
In our lab, we are trying to do real time PCR for some genes. One of them has a size of 85 bp. Whatever we do, we had an amplification in negative control. When we run agarose gel, it always a...
14 February 2021 9,750 11 View
Hi everyone. We want to know how can I remove the non-specific band amplification on this variant. Although the amplification of non-specific band is not as intense as the band that we want, but...
09 February 2021 588 2 View
Till now i haven't got any PCR amplified vp2 gene bands on specific annealing temperature and in step up PCR.
08 February 2021 819 4 View