I've tried Qiagen RNeasy and Trizol but the yield and quality (RIN ~2.8) is quite poor. The cards are spotted with fresh blood and left for 2 hours to dry at room temperature. I perform extraction using the exact same protocol on whole blood in parallel and consistently get RIN scores >7 whilst. Any advice?

More Sarah Furlong's questions See All