Sometimes, the message "Gel Leak" appears in the second run with the same polyacrylamide gel, but nothing is leaking.
The system pause when give the message. I will try to check again the apparatus but I noticed that in the second run, appear condensed buffer near the camera, maybe that is the problem. Tks for your help!
My bands are appearing, but very weak and I always saturated the image to see strong bands.
05 June 2013 7,861 5 View
Hi, I have problems with running gel electrophoresis. I have tried agarose gel electrophoresis and native PAGE. I have two proteins, which have molecular weights of ~30kDa and ~180kDa and two...
03 March 2021 4,275 4 View
Gel electrophoresis, RNA degradation, RNA extraction from fresh tissue
02 March 2021 5,433 5 View
I'd like to perform single-strand conformation polymorphism (SSCP) in my thesis, however I cannot control the temperature of the vertical PAGE since we are using the conventional tanks. Is there a...
02 March 2021 9,157 1 View
Can someone please give me some possible things that could go wrong? Here is my recipe: 0.5g Agarose 50 mL of TAE 1x 1 uL ethyl bromide. Gel was run at 100V for 1 hour. The buffer used is also TAE.
01 March 2021 9,952 3 View
Hi, I am running a size exclusion chromatography experiment with a buffer containing Potassium Acetate as a salt. I analyse these fractions through SDS-PAGE. After boiling my SEC fractions in...
01 March 2021 2,622 3 View
If I want to compare characteristics of 2 groups of patients, one group is recruited from a random sample of the general public while another group is from a sample with a fixed gender (male to...
26 February 2021 3,526 3 View
I am worried about this overexposure of the upper part of the gel in the picture. Is it possible that this is the result of too much concentration of ethidium bromide? Why is there such a big...
25 February 2021 8,140 3 View
I tried to separate my substance from a protein in a sillica gel column. By mistake, it dried and cracked. Can I save the trapped substance? Can I repack it ,or at least elute all of the trapped...
22 February 2021 1,789 3 View
This is gel electrophoresis result for total RNA samples with good conc. However, I guess there is a problem with the purity of the samples, i can't figure out why it appears like this? And how...
22 February 2021 338 9 View
Hi all, I proceed with nucleic acid gel electrophoresis recently several times, but a wried phenomenon is they always melted after running over 30min. My gel concentration is 1% percentage...
22 February 2021 9,896 3 View