Hello people, I am seeing this weird behavior while running a simulation, any idea how to fix it?
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,801 2 View
I want to refine one XRD peak of my in-situ xrd but the background is never working good which ultimately fails the refinement. How to refine and adjust the background using GSAS-II
05 August 2024 5,291 2 View
I am attempting to conjugate PEG to an amino acid at the C-terminus, for the purposes of producing nanoparticles. I have been told that PEG modified with amine groups can be used for this purpose,...
31 July 2024 2,033 1 View
The entropy measured of molecular graphs plays a crucial rule. The network structures in some cases are very lengthy calculations to handle. Some author avoid to construct table where as most...
30 July 2024 3,126 0 View
Am trying to develop a lesson/lab to determine and compare antioxidant properties of soybeans of various colors. Preference would be low tech and low cost. Any assistance is greatly appreciated.
25 July 2024 7,498 2 View
In running two-dimensional gel electrophoresis on bacterial protein, some spots that appear to match a protein sequence have a significantly more acidic isoelectric point than the calculated pI....
24 July 2024 8,076 3 View
The first step is to analyze a 2D molecular graph and implement partitioning techniques to calculate the topological indices. Secondly impose statically tools to generate QSPR model, may or may...
24 July 2024 9,644 1 View
Most of the time it is observed that in many manuscripts there are several typo error of topological calculation errors of calculation and partition of edges what ever the type of partitioning it...
22 July 2024 811 0 View
Their is new research published in the biological control journal, and I am one of the authors. I want to add it to my account at researchgare. How can I do this?
21 July 2024 7,545 0 View
I have read that it is better to use other research methods alongside document analysis for triangulation, although it can also be used as a stand-alone method.
18 July 2024 4,218 0 View
I’m trying to reproduce the acousto-optic coupling simulation in the paper Frequency–angular resolving LiDAR using chip-scale acousto-optic beam steering. LNOI(lithium niobate on insulator) is...
13 August 2024 9,795 0 View
Dear QE-users, In the method where full MS positive mode and PRM mode are used, we always get an incorrect auxiliary gas reading (41 instead of 25). This only happens in this method; other...
06 August 2024 4,953 0 View
Hello guys! Do you have experience running a Oaxaca-Blinder decomposition on R applying person weights. How do you suggest doing it? I have a variable PERWT which gives more information on how...
04 August 2024 6,033 0 View
For a grid connected BESS (lets say 100 MW/200 MWh system, LFP battery), if we charge the BESS in such a way that whenever we can access power from the solar that will charge the BESS. Hence it...
01 August 2024 9,903 7 View
I need to Postfix mice brains. I slice the brains using microtome at 40 microns. These are Postnatal days 7, 11, 14, and 21. I am using half the brain for other analysis, so I need to fresh freeze...
31 July 2024 1,123 4 View
Hello Everyone I have a question about structure for connectivity analysis on sources. My goal: preprocess and cut data into trials create headmodels, using template MRI file perform source...
30 July 2024 2,744 1 View
When I run autogrid4 it says: autogrid4: ERROR: Unknown receptor type: "Cr" -- Add parameters for it to the parameter library first! Look forward to your reply.Thank you so much!
29 July 2024 488 0 View
I am trying to run a restart analysis, which imports deformed configurations of parts from a generated ODB file. It runs fine in Windows OS but when I try to run it in Linux OS, it is giving some...
29 July 2024 9,572 3 View
Our department has recently acquired an HPC (High-Performance Computing) system, and I'm thrilled to take my molecular dynamics calculations to the next level using Desmond. I used to run my...
28 July 2024 6,553 1 View
I am preparing to run a lot of samples on a 384 well plate and I wanted to test if any well in my PCR machine is dead so as not to lose any data. I would really appreciate help with how I can do...
24 July 2024 8,172 1 View