want to compare the bond lenth and angle obtained from DFT with the parameters obtained from the XRD.Many paper shows that they obtained parameters from the powder xrd itself.please suggest me some methods.
Hi,
I suggest Jana2006 :http://jana.fzu.cz/
I also use FullProf. https://www.ill.eu/sites/fullprof/
Both for free.
GSAS and fullprof are all very good one. Youc an get them from internet. just google them.
Fullprof program, Maud Program and GSAS.
The site to download the fullprof is
https://www.ill.eu/sites/fullprof/php/downloads.html
Maud
http://maud.radiographema.com/
refer Fullprof program
You can try it following order:
1. DWBS
2. FullProf.
3. GSAS
Thank you for your valuable suggestions
You may download free for powder XRD and neutron powder diffraction from Internet.
I have a polymer electrolyte? I would like to take it's cv too...But i don't know the exact methood to take it's cv.which is the best method? Three electrode method or solution methoD?please tell...
09 October 2016 5,341 0 View
i have done DFT B3LYP theory with PBE basis set for polymers defined by periodic boundery condition. what data will getv from this
05 June 2016 4,560 0 View
Hi, I am after the reference below, my library says it cannot obtain a copy either locally or internationally, any help appreciated! Chris Wang ZM, Heshka S, Wielopolski L, Pi-Sunyer FX, Pierson...
03 March 2021 6,193 1 View
i am try to classify the x-ray images. During classification , can i block unwanted images (except x-ray image).
03 March 2021 7,100 1 View
01 March 2021 1,290 2 View
When you observe the presence of Tyndall in an inflamed eye: Does each of the small floating dots correspond to an individual cell or to an aggregate of cells? Does a conventional slit lamp have...
27 February 2021 6,326 2 View
27 February 2021 2,753 4 View
I have tried every combination of parameter changes and after that i have a poor chi square value. I can't get it lower any further. I know there have been a lot of discussion about Rietveld...
26 February 2021 8,480 3 View
I am working on TiO2 composite material and the results of XRD have a lot of small/junk peaks and while I apply a smooth filter in Origin then the other characteristics peaks disappear so anyone...
26 February 2021 8,183 3 View
I had a crystal hit in a well with 0.1M HEPEs pH 7.5, 10%(w/v) PEG 4000, and 20%(w/v) isopropanol. Why is isopropanol in w/v here if it's just solvent? How do I recreate this well condition?
25 February 2021 9,761 1 View
i am trying to download x'pert high score software, but can't download it. please do suggest software for phase analysis
24 February 2021 5,687 4 View
I am refining my XRD data using in FullProf program. The intensity of the modulated X-ray peaks is almost flat. I tried to adjust the peak intensities but unsuccessful. What is the reason? I guess...