Because I need to find out some nano biosensors to study.
Nanobiosensors are available/developing for different fields:
Biosensors 2016, 6(1), 10; https://doi.org/10.3390/bios6010010
Nano-Biosensors: NextGen Diagnostic Tools in Agriculture. In: Hakeem K., Pirzadah T. (eds) Nanobiotechnology in Agriculture. Nanotechnology in the Life Sciences. Springer, Cham., 2020, https://doi.org/10.1007/978-3-030-39978-8_7
Sensors 2020, 20(23), 6926; https://doi.org/10.3390/s20236926.
Try this: https://link.springer.com/chapter/10.1007%2F978-3-319-58679-3_1
Dear researchers, I tried and understood that PLA dissolves well in the solvent mixture of DCM and Ethanol. It also dissolves well in DMF, Acetone, THF and Chloroform efficiently. But does anyone...
23 April 2024 6,622 4 View
Dear all, I am using AutoDock Vina to obtain the binding free energy of a ligand and a crystal surface. Using ADFR suites to convert input file from pdb to pdbq, I use prepare_receptor -r...
04 December 2023 9,970 0 View
Hey guys, I tried electrospinning PLA nanofibers on aluminium foil. I was able to achieve thicker fibers by increasing the viscosity of the solution. However, the fibers stick to the aluminium...
03 December 2023 3,417 5 View
Hey guys, By tweaking the viscosity of my polymer solution, I was able to obtain thicker PLA films after electrospinning. However, I am unable to separate the PLA polymer film from the aluminium...
14 November 2023 2,188 2 View
I have heard certain good things about Metal Injection Moulding, specially the fact that it can produce very accurate parts. Moreover, it also makes the manufacturing of complex- design parts look...
29 October 2023 956 0 View
Hello everyone, I electrospun the PLA fibers onto the aluminum foil. Upon drying in air, the PLA fibers stuck onto the aluminum foil and am unable to peel them off for further characterization....
26 September 2023 9,187 0 View
Hi guys, Upon searching the literature, I found that DCM and DMF were the most commonly used solvents for electrospinning PLA polymer. Can you please tell me what other alternate solvents can I...
13 September 2023 7,507 4 View
Hello everyone! I have interesting question asked by my professor and I could not find relevant answer anywhere. Why are we seeing up and down pattern on transcript abundance? Example RNA seq data...
19 January 2023 9,289 4 View
I have used wet samples and dried film samples for Tg in DSC but I could not get any major peak.
04 August 2022 8,714 2 View
Supposing that a cooling tower is installed in a region which is extremely humid. Given the fact that the wet bulb temperature will be high, in these type of conditions, the delta T between the...
28 June 2022 8,055 0 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
Is anyone here using the Thermo Fisher Nano Orange kit for protein quantification, and detecting the fluorescent signal on the Promega Quantus? We are struggling to make sense of the standard...
05 August 2024 8,946 3 View
I work with planar interdigitated electrodes (IDEs). The finger width and the spacing between the fingers are 5 micron. The surface of the IDEs is coated by a non-conductive polymer layer...
16 July 2024 5,031 1 View
Hi all, if you are looking for PhD and Master opportunity to work on Microalgae research and Biosensor for bacteria detection. Please do not hesitate to email me [email protected]
07 July 2024 7,576 0 View
Hi, I am doing aptamer based electrochemical biosensor. First, I cleaned screen printed gold electrode using 0.5M H2SO4. Then, immobilized aptamer followed by blocking using 2mM MCH. I use...
06 July 2024 9,852 1 View
Some scientists use nano nitrogen and some use nano urea, even though the process used the same for preparation. So, which is true nano nitrogen or nano urea?
28 June 2024 2,885 6 View
Suppose I need to target mitochondria to address malignancy-related problems. Are there peptide-based ligands similar to Nuclear Localization Signals (NLS) for nuclear targeting that can be used...
20 June 2024 9,587 1 View
I am working with chitosan/dextran sulphate nanoparticles loaded with rifampicin, which is fluorescent. Dsl analysis are bad and I saw that is necessary use a narrow band filter. How can I select...
05 June 2024 1,324 3 View
What is the difference between absorption and adsorption?
30 May 2024 4,447 27 View
nano additives and lubricants for hybrid electric vehicles
24 May 2024 8,363 3 View