12 Questions 20 Answers 0 Followers
Questions related from Purvi Kikani
I am working on fabricating anti-bacterial polymer surface using surface modification techniques. I would like to understand whether substantial reduction in bacterial adhesion on to polymeric...
07 July 2018 503 1 View
what is the origin and significance of writing imaginary term exp i(kx-wt) in the wave equation ?
01 January 2018 3,289 12 View
We consider small perturbation in plasma to understand the concept of plasma oscillation. We take perturbation in velocity, density and electric field. que-1 how do we create this perturbation...
01 January 2018 7,685 6 View
In case of electron plasma waves we consider adiabatic compression and take gamma equal to 3 [using equation (2+N)/N]. what do we mean by adiabatic compression here?I mean physical significance....
01 January 2018 9,638 1 View
I am depositing SiOx films using HMDSO / Oxygen gas mixture by low pressure RF PECVD method. In FTIR spectra I get two overlapped peaks around 1050 cm-1 and 1135 cm-1. Does this have any relation...
10 October 2015 9,996 9 View
I am giving a plasma treatment to polyethylene (PE) surface. Wetting time (time taken to completely wet the PE surface) on plasma treated polymer surface changes as a function of one of my...
04 April 2015 7,245 6 View
I am trying to see the presence of functional groups on air plasma treated polyester / PET surface by ATR-FTIR method. Getting good wettability improvement after plasma treatment, but unable to...
07 July 2014 7,736 17 View
I want to develop a patterned super hydrophobic/hydrophilic surface on a glass/silicon surface. Please suggest any methods that involve plasma processing without the use of halogens.
06 June 2014 1,267 2 View
I want to understand the effect of plasma parameters on coating characteristics for deposition of SiOx and SiOxNy thin films using the PECVD method.
05 May 2014 9,242 2 View
I want to understand how gas transmission rate is dependent on the thickness of the diffusion barrier coating deposited on a polymer substrate. Why is the preferred thickness of the diffusion...
04 April 2014 2,617 6 View
I am depositing SiOx film from HMDSO / Oxygen mixture. I am observing shift in the Si - O - Si peak at 1056 cm-1 towards a lower or higher wave number side while varying experimental parameters....
04 April 2014 1,124 11 View
And how much does it increase after IR absorption? What is the change in bond length at a natural frequency of vibration and at a given IR energy, for the C=O bond for example?
03 March 2014 7,543 4 View