In machine design does any changes required for connecting stator winding in Star or Delta. How to identify, the machine is designed for star or delta.
21 March 2024 5,660 3 View
Dear researchers, How to implement fuzzy in dSPACE1104. By replacing the speed PI control with fuzzy controller getting over run error. How to resolve it. does any seperate settings has to be...
29 July 2021 4,809 4 View
Comparison of different Micro Controllers and its features. Every micro controller has specific gui interface. In which, dSPACE specifically has online control feature. Except that what are the...
24 February 2021 5,440 6 View
IN simulation, we may select park or modified park model based on your equations. But when come to Hardware, How to know, which model it belongs.
05 October 2020 172 0 View
PMSM need initial rotor position to provide proper sequence of supply.But, How initial position incorporated in FoC.
05 October 2020 3,477 2 View
No load current of the PMSM motor w.r.to full load current. Compare with Induction and synchronous motors.
24 February 2020 7,392 1 View
To start PMSM motor we need initial rotor position of PMSM drive to have sequential supply, in order to avoid magnetic locking. But how sensor less PMSM starts without knowing rotor position?
31 December 2019 4,422 2 View
PMSM (Permanent Magnet Synchronous Motor)