For a long time I am dealing with a problem with MD simulation.

I want to simulate a system composed of a lipid bilayer with two separated "baths" of water with ions inbalance. My protocol works in all my systems except one.

I have diagnosed that when I don't move any ions after equilibration, the system works (the simulation starts), but when I want to move one ion, the error occurs:

" Fatal error:

of the domain decomposition cell of their charge group in diamension x.

4 particles communicated to PME rank 2 are more then 2/3 times the cut-off out of the domain decomposition cell of their charge group in diamension x.

This usually means that your system is not well equilibrated."

The only files that GROMACS produce are: .log (with 0 steps), .xtc, .trr and .edr.

What would You suggest to do? I am dealing with the problem for a month and still no progress...

More Wojciech Szlasa's questions See All