Dear Researchers,

                               I'm working on a bridge circuit that is connected to an instrumentation amplifier AD623.  The differential inputs to the amplifier from the bridge (-IN and +IN) reads 2.45V each respectively implying the balanced condition of the bridge. I used a resistor gain of 218 Ohms . So am expecting the output to be amplified 458 times the differential input. However, the output always reads 3.83V irrespective of the resistor gain I use. I used two different power sources to power my bridge and amplifier (say +5,-5V respectively). Why is this problem occuring? I clearly see the problem occurs only after amplification. Before amplification, the tester reads almost zero voltage. In some articles, I see people are using two capacitors across the positive voltage source of amplifier (Please see attached figure). Any help would be much appreciated. Thank you